[Repeater-Builder] Re: [Micor] Micor Cont duty base help

2004-08-03 Thread Eric Lemmon
Kevin, The RXB MICOR is a Digital Voice Protection model, of which I have several. It uses a TLN5979A backplane instead of the more common TLN5644A. You MUST use the TLN5970A Station Control Module with the DVP backplane, as it has many critical connections that are different from the more

[Repeater-Builder] RE: [Micor] Micor Cont duty base help

2004-08-03 Thread Kevin Bednar
Eric, I have confirmed I have the TLN5979A backplane, and do indeed have the TLN5970A SCM. Can you email me what I need to do to config this unit to use an external controller? I have the TX and RX working fine seperately, just need to interface the controller. Thanks! Kevin From: