RE: [Repeater-Builder] Re: MSF-5000 PL encode deviation

2008-12-22 Thread Eric Lemmon
seldom can hear the tone. 73, Eric Lemmon WB6FLY -Original Message- From: Repeater-Builder@yahoogroups.com [mailto:repeater-buil...@yahoogroups.com] On Behalf Of nj902 Sent: Friday, December 12, 2008 1:16 PM To: Repeater-Builder@yahoogroups.com Subject: [Repeater-Builder] Re: MSF-5000 PL

[Repeater-Builder] Re: MSF-5000 PL encode deviation

2008-12-12 Thread nj902
The original factory design specification for the MSF5000 PL deviation is 800 Hz. That is just slightly greater than the 750 Hz. mid point in the acceptable range of 500 Hz to 1000 Hz as given in TIA-603. One issue that can cause the PL level to be incorrect is failure to properly perform the

RE: [Repeater-Builder] Re: MSF-5000 PL encode deviation

2008-12-12 Thread Ralph Hogan
-Builder] Re: MSF-5000 PL encode deviation The original factory design specification for the MSF5000 PL deviation is 800 Hz. That is just slightly greater than the 750 Hz. mid point in the acceptable range of 500 Hz to 1000 Hz as given in TIA-603. One issue that can cause the PL level