Hi Aravind,
Please note that OF v1.3.4 introduced the "new IANA TCP port of 6653" and
most switch vendors implemented OF v1.3.1.
I wouldn't be surprised if your application would work right away if you'd
stick to the "old standard".
Benny
On Sat, Dec 27, 2014 at 7:04 PM, Aravindhan Dhanasekaran
Hi Aravind,
I see that the TCP ports differ from the "working" and "non-working"
example (6633 vs 6653). Did you try to take a packet capture with Wireshark?
If the communication stops so suddenly, it feels like coming from such a
topic.
-Benny
On Fri, Dec 26, 2014 at 11:20 PM, Aravindhan Dhanas
Hello,
I'm using OpenFlow reference implementation v1.3 switch (CPqD/Ericsson) and
Ryu controller.
My Ryu controller app is based on the L2 forwarding switch example.
Whenever I start my controller, it receives the 'hello' message from the
switch and goes to config mode. It just freezes in the con