[sane-devel] Autotools generated files and CVS

2009-01-19 Thread Olaf Meeuwissen
Chris Bagwell chris at cnpbagwell.com writes: On 1/17/2009 3:20 AM, Julien BLACHE wrote: Chris Bagwellchris at cnpbagwell.com wrote: I've not seen this discussed in mailing list archive. Is there any past discussions? We leave autotools files in CVS because: - it's a pain to

[sane-devel] Autotools generated files and CVS

2009-01-19 Thread Olaf Meeuwissen
Chris Bagwell chris at cnpbagwell.com writes: On 1/18/2009 8:50 PM, Olaf Meeuwissen wrote: See also, http://www.gnu.org/software/gettext/manual/html_node/Files-under-CVS.html#Files-under-CVS. Agree with all your comments... Also, here is similar link from Automake that describes cvs

[sane-devel] genesys backend update

2009-01-19 Thread stef
Hello, the genesys backend as been updated. Thanks to an hardware donation of Jack McGill, there is now support for the sheet-fed Visioneer Strobe XP200. It can scan at 75, 100, 200, 300 and 600 dpi in color or gray and at 8 or 16 bits. Scans are uncalibrated, ie there is no

[sane-devel] Avision AV122 and reading the buttons gives I/O-Error

2009-01-19 Thread Wilhelm Meier
Am Sonntag 18 Januar 2009 schrieb Zudio Solutions: Hi Wilhelm, I writing to you in response to your effort to get the AV122 to work with sanebuttond (post: http://lists.alioth.debian.org/pipermail/sane-devel/2008-November/0 23144.html ) did you manage to get this working? Yes. It is the

[sane-devel] Autotools generated files and CVS

2009-01-19 Thread Julien BLACHE
Olaf Meeuwissen olaf.meeuwissen at avasys.jp wrote: Hi, Not doing so will make for a lot of big commits. And? What's the point? As long as the build system updates are self-contained and not mixed with other changes in the tree, we couldn't care less. As we also discussed maintaining our

[sane-devel] Severe problem with Mustek A3 USB

2009-01-19 Thread Aribert Deckers
Hello, I have a problem with a Mustek A3 USB for scanning xray film: Using SANE for scanning the transparency lid for scanning xrays is sending light into the scanner, but the lamp in the scanner is not turned off whilst scanning, so the xray film is lit from 2 sides and the scans are very bad

[sane-devel] Test git repositories available

2009-01-19 Thread Julien BLACHE
Hi, I am making available test git repositories for SANE. They look exactly like the real repositories will look when we do the switch; they're based on CVS 3-4 days ago, and they do NOT track the CVS. *** THESE ARE TEST REPOSITORIES, DON'T USE THEM FOR ANY SERIOUS WORK *** The repositories

[sane-devel] addendum to 55-libsane.rules for brother MFC-7840W

2009-01-19 Thread Jochen Lauber
Dear Sirs, please be informed, that I added under Opensuse 11.1 on AMD 64 following entry to 55-libsane.rules for the scanner inside the MFC-7840W of www.brother.com. The brscan3 driver of brother is used. === # Brother MFC-7840W