On Thu, 28 Aug 2008 00:28:40 +0200 Francesco Poli wrote:
[...]
It seems that Debian does not include the umax_pp tool; I've just
reported this missing as a (wishlist) bug:
http://bugs.debian.org/496833
Update: the umax_pp tool has been included in the Debian package in
response to my wishlist
On Wed, 27 Aug 2008 06:42:15 +0200 stef wrote:
[...]
use the -r switch of the umax_pp command line tools.
I've just done so and the lamp was reset to the ready position!
I saw some errors written to stderr, but the lamp got back home!
Then, after unplugging and replugging the scanner, I
Le Tuesday 26 August 2008 22:33:35 Francesco Poli, vous avez ?crit?:
Hi all!
I have an HP ScanJet 3200C parallel port scanner, which seems to
work with the umax_pp backend.
I am using Debian GNU/Linux (testing branch), which includes
SANE version 1.0.19.
During a scan with
$ scanimage
Hi all!
I have an HP ScanJet 3200C parallel port scanner, which seems to
work with the umax_pp backend.
I am using Debian GNU/Linux (testing branch), which includes
SANE version 1.0.19.
During a scan with
$ scanimage -d umax_pp --format tiff --mode Color --resolution 300 out.tiff
I