This reader resets each inserted card twice? That's strange... I'm aware
of special cards that change their behaviour after a second reset is
performed while the card is still powered on... These cards couldn't then
be used in such a reader...
On Tue, 27 Feb 2001, David Corcoran wrote:
Hi
David,
Why reset the card twice? ISO doesn't say that the card must always give the
same ATR from a warm reset as from a cold reset, and EMV in particular take
advantage of this to insist that the card must send a 'basic ATR' (i.e. one
which says 'I will run with the startup parameters, but here