MUSCLE Litronic Argus 210 and Cyberflex Access

1999-05-04 Thread Jeremy Impson
I just built (with debugging) and installed PCSC 0.101 and am trying to use it with the Litronic Argus 210 and Cyberflex Access card. When running pcscserver and test_insertion I get the following: from test_insertion: root@dunkirk:/usr/local/pcsc/bin# ./test_insertion 0)

Re: MUSCLE Litronic Argus 210 and Cyberflex Access

1999-05-04 Thread David Corcoran
Hi, Your problem is probably in card.conf. The reader activated fine but it either couldn't match a card in card.conf or could not find the library for that card. Look at the ATR returned by pcscserver and match it with the ATR in card.conf. Make sure everything is working correctly there.

Re: MUSCLE Litronic Argus 210 and Cyberflex Access

1999-05-04 Thread Jim Rees
Yes, a new Cyberflex Access card was released on March 19, and kits delivered after that date have the new card. The old card atr ends with 0f, the new one ends with 1f. There are three changes, ChangeJavaATR has been fixed, SetKey now works with the key in a byte array, and the serial number