I just built (with debugging) and installed PCSC 0.101 and am trying to
use it with the Litronic Argus 210 and Cyberflex Access card.
When running pcscserver and test_insertion I get the following:
from test_insertion:
root@dunkirk:/usr/local/pcsc/bin# ./test_insertion
0)
Hi,
Your problem is probably in card.conf. The reader activated fine but it
either couldn't match a card in card.conf or could not find the library
for that card. Look at the ATR returned by pcscserver and match it with
the ATR in card.conf. Make sure everything is working correctly there.
Yes, a new Cyberflex Access card was released on March 19, and kits
delivered after that date have the new card. The old card atr ends with 0f,
the new one ends with 1f. There are three changes, ChangeJavaATR has been
fixed, SetKey now works with the key in a byte array, and the serial number