Dne 05. 08. 22 v 20:18 Kevin O'Connor napsal(a): > On Wed, Jul 13, 2022 at 03:25:17AM +0200, Petr Cvek wrote: >> ASPI2DOS.SYS and KEYB.COM from Win 98 SE installation CD (and most likely >> other DOS versions too) depend on I/O port 0x61 bit 4 to be toggled. This >> requires timer 1 (I/O 0x41,

[SeaBIOS] Re: [PATCH] timer: Configure timer1 to a standard settings

2022-08-06 Thread Peter Stuge
Kevin O'Connor wrote: > > Also Intel ICH7 Family Datasheet, chapter 5.8 states: > > > > Programming the counter to anything other than Mode 2 will result in > > undefined behavior for the REF_TOGGLE bit. > > > > Failing to have the timer 1 configured indeed causes affected OSes to > > freeze

[SeaBIOS] Re: [PATCH] timer: Configure timer1 to a standard settings

2022-08-05 Thread Kevin O'Connor
On Wed, Jul 13, 2022 at 03:25:17AM +0200, Petr Cvek wrote: > ASPI2DOS.SYS and KEYB.COM from Win 98 SE installation CD (and most likely > other DOS versions too) depend on I/O port 0x61 bit 4 to be toggled. This > requires timer 1 (I/O 0x41, legacy DRAM refresh) to be correctly set. > Also Intel