Re: [Sepsis Groups] Respiratory rate for SIRS on ventilator

2018-10-02 Thread Belfi, Karen
Are you using the vent for organ dysfunction? If so it would be out of the window because it was initiated the prior day. I had asked CMS and you only use initiation of ventilator for organ dysfunction. Also, if the vent was set for 22, then you wouldn't use it. If the patient was breathing

Re: [Sepsis Groups] Respiratory rate for SIRS on ventilator

2018-10-02 Thread Knight Elizabeth
If the ventilator was set at 22 and is charted as such, you do not count the RR as part of the SIRS component. Here's the example from the definition: "SIRS criteria or a sign of organ dysfunction due to artificial interventions should not be used. Example: Mechanical ventilator rate set at 24

Re: [Sepsis Groups] Respiratory rate for SIRS on ventilator

2018-10-02 Thread Tara Miller
Was the vent set on 22 respirations? Or did the physician/nursing just document "therapeutic" for the patient. If the vent was not set on 22 then you could still use the 22 respiratory rate as SIRS. Tara -Original Message- From: Sepsisgroups On Behalf Of Jeanie Bollinger Sent: