Hi Esmaeil,
I can see that you have atomic positions that are below the origin (0.0 0.0
0.0) try to shift your entire sistem, in a way that all positions in Z
direction get positive values. Then start a new calculation from scratch,
this might help.
2017-08-31 5:25 GMT-03:00 Esmaeil Farajpour
Dear Esmaeil,
You have a very large vacuum gap behind your electrode, this may cause
problems in the SCF convergence.
Then a couple of comments:
1) There is practically no point in having k-points along the transport
direction for the scattering calculation. So set the last diagonal k-point
to
Try using larger electrodes
-Original Message-
From: "Esmaeil Farajpour Bonab"
Sent: 9/1/2017 1:30 AM
To: "siesta-l@uam.es"
Subject: [SIESTA-L] SCF convergence problem in Transiesta 4.1-b3
Dear Transiesta users,
I am studying the transport