Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-02-09 Por tôpico Ziba Torkashvand
I really appreciate your help. Finally I have changed the inputs based on your advise and similar to the example of Au_100. Unfortunately, I still receive the following error. Here is my corrected inputs. Thanks a lot. k-point displ. along 1 input, could be: 0.000.50 k-point displ. alon

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-02-07 Por tôpico Nick Papior
Like I mentioned, your lattice vectors are not parallel, see device lattice vectors and electrode lattice vectors. They need to be parallel in case you want to use k-points. Den man. 3. feb. 2020 kl. 22.10 skrev Ziba Torkashvand < zi.torkashv...@gmail.com>: > These are my input files for the devi

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-02-03 Por tôpico Ziba Torkashvand
These are my input files for the device and electrodes. On Mon, Feb 3, 2020 at 9:32 AM Ziba Torkashvand wrote: > Thanks for your response Nick, > Previously, I have used the following lattice vectors for the device > %block LatticeVectors > 24.8355890 0.0312245 -0.2325957 >0.0300392 22

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-02-03 Por tôpico Ziba Torkashvand
Thanks for your response Nick, Previously, I have used the following lattice vectors for the device %block LatticeVectors 24.8355890 0.0312245 -0.2325957 0.0300392 22.4960510 -0.2979615 -0.2501458 -0.3417446 26.7881732 %endblock LatticeVectors and %block LatticeVectors 15.5329 0

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-01-23 Por tôpico Nick Papior
Hi, Sorry, I don't understand your response. I referred to the lattice vectors in the two calculations not being parallel. It is not due to your k-point samplings. Den ons. 22. jan. 2020 kl. 22.01 skrev Ziba Torkashvand < zi.torkashv...@gmail.com>: > Actually, I just have two electrodes (in the

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-01-23 Por tôpico El-abed Haidar
Physics THE UNIVERSITY OF SYDNEY | NSW | 2006 From: siesta-l-requ...@uam.es on behalf of Ziba Torkashvand Sent: Wednesday, 22 January 2020 1:46 PM To: siesta-l@uam.es Subject: Re: [SIESTA-L] Erroneous electrode setup, check out-put Actually, I just have two

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-01-22 Por tôpico Ziba Torkashvand
Actually, I just have two electrodes (in the y-direction) and both of them are perpendicular to the device region (in the z-direction). As I see in the example of Au 111 it has the largest kpoint along the semi-infinite direction of electrodes for the electrode run (2 2 10) which in my work is in t

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-01-21 Por tôpico Nick Papior
Hi, Your 3rd electrode and device lattice vector are not parallel. Please make sure they are parallel. :) Den man. 20. jan. 2020 kl. 22.04 skrev Ziba Torkashvand < zi.torkashv...@gmail.com>: > Hello everybody > I want to do a transiesta calculation with Siesta 4.1-b4. > In my device, two bulk el

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-01-21 Por tôpico Adeel ahmed awan
hi , i am sorry i can't able to reply right answer but i need some help. in your above k grid block 0.000, 0.000,and 0.50 indicate which parameter or what are their meanings. On Tue, Jan 21, 2020 at 2:00 AM Ziba Torkashvand wrote: > Hello everybody > I want to do a transiesta calculation with Si

Re: [SIESTA-L] Erroneous electrode setup, check out-put

2020-01-21 Por tôpico El-abed Haidar
Hello Ziba As far as I understand the k points of electrode and scattering have to be the same which you have not done. Make sure of being consistent between electrode and scattering calculations in everything Good luck El abed Sent from my iPhone On 21 Jan 2020, at 8:01 am, Ziba Torkashvand m

[SIESTA-L] Erroneous electrode setup, check out-put

2020-01-20 Por tôpico Ziba Torkashvand
Hello everybody I want to do a transiesta calculation with Siesta 4.1-b4. In my device, two bulk electrodes are on the top of a monolayer hexagonal system. The transport direction is in z direction so the electrode direction is y. I have used kpoint sampling 1 0 0 0 20 0 0 0 40 for the electrodes a