Could you try with a nonzero eta for the electrodes?
Same goes for transiesta calculations with bias.
Say a value of 1e-4 eV.

One cannot use eta==0 since the dos explodes if you hit an eigenstate.

On Sat, 25 Jul 2020, 07:12 赵鸿远, <zhy...@tju.edu.cn> wrote:

> Dear all,
>     I am using siesta4.1-b4 version. I want to calculate I-V curve for my
> system. My scf and ts-scf calculations were done successfully with
> transiesta code. An error occurs  when I run tbtrans program to extract
> data.
> the screen shows following error:
>
> tbt: LHS Green function padding / memory: 715712 /   23.730 MB
> tbt: RHS Green function padding / memory: 129600 /   14.787 MB
> TT_eigen: Could not calculate eigenvalues.
>
> Intel MKL ERROR: Parameter 3 was incorrect on entry to ZGEBAL.
>
> Intel MKL ERROR: Parameter 4 was incorrect on entry to ZHSEQR.
>           -4
> TT_eigen: Could not calculate eigenvalues.
> Stopping Program from Node:   22
> Stopping Program from Node:   22
>
>
> Could someone help me solve the problem?
>
>
> Thanks,
>
> Zhao HY
>
>
>
-- 