Dear Andrei
> Thank you for your reply.
>
I attached two files. One is for 1 unit cell and the other is for 2 unit
cell to the z-direction.
Would you test these files?
Joonho
Au.fdf
Description: Binary data
Au112.fdf
Description: Binary data
Dear Joonho,
at first sight there is no error of input, but you don't give
your entire input file.
What are your
LatticeConstant
AtomicCoordinatesFormat
and
NumberOfAtoms
as defined by you and (more important)
recognized by the system? What are the cordinates
printed out in the output file?
Bst re
Dear users
I have run a basis parameter for Au in a recently published paper in siesta.
It worked very good.
In my calculation I used 4 atoms in unit cell.
But when I tried to use 8 atoms for 2 unit cell, it made error like this.
What is this problem and how to deal with this?
* Maximum dynamic m