Please find attached logs for the Western Digital WD5003ABYZ which is not in the current smartmontools database. -- Adam Piggott, Proprietor, Proactive Services (Computing)
smartctl 6.4 2015-06-04 r4109 [i686-w64-mingw32-win7] (sf-6.4-1) Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION === Device Model: WDC WD5003ABYZ-011FA0 Firmware Version: 01.01S03 User Capacity: 500,107,862,016 bytes [500 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ATA8-ACS (minor revision not indicated) SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s) Local Time is: Wed Nov 11 18:09:15 2015 PST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 41) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: ( 8160) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 83) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 138 133 021 Pre-fail Always - 4100 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 42 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0 9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 10355 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 42 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 27 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 136 194 Temperature_Celsius 0x0022 107 100 000 Old_age Always - 36 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Interrupted (host reset) 90% 10353 - # 2 Short offline Completed without error 00% 10198 - # 3 Short offline Completed without error 00% 10030 - # 4 Short offline Completed without error 00% 9863 - # 5 Short offline Completed without error 00% 9695 - # 6 Short offline Completed without error 00% 9527 - # 7 Short offline Completed without error 00% 9360 - # 8 Short offline Completed without error 00% 9227 - # 9 Short offline Completed without error 00% 9059 - #10 Short offline Completed without error 00% 8918 - #11 Short offline Completed without error 00% 8750 - #12 Short offline Completed without error 00% 8582 - #13 Short offline Completed without error 00% 8415 - #14 Short offline Completed without error 00% 8364 - #15 Short offline Completed without error 00% 8234 - #16 Short offline Completed without error 00% 8066 - #17 Short offline Completed without error 00% 7920 - #18 Short offline Completed without error 00% 7752 - #19 Short offline Completed without error 00% 7596 - #20 Short offline Completed without error 00% 7428 - #21 Short offline Completed without error 00% 7260 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database