Hi, I have a Plextor PX256-M3P, which is making some trouble. That's why I issued multiple selftest commands. When inspecting the selftest logs, I wondered about the LifeTime, which is completely different from SMART attribute 9. The attached log shows the situation. I would be glad if you could correct the display of the selftest logs for this drive type.
smartctl 6.4 2015-06-04 r4109 [x86_64-w64-mingw32-win7-sp1] (sf-6.4-1) Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION === Model Family: Plextor M3/M5/M6 Series SSDs Device Model: PLEXTOR PX-256M3P Add. Product Id: VRPR Firmware Version: 1.06 User Capacity: 256.060.514.304 bytes [256 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a SATA Version is: SATA 3.0, 6.0 Gb/s Local Time is: Tue Dec 22 16:19:45 2015 MZ SMART support is: Available - device has SMART capability. SMART support is: Enabled AAM feature is: Unavailable APM feature is: Unavailable Rd look-ahead is: Enabled Write cache is: Enabled ATA Security is: Disabled, NOT FROZEN [SEC1] Wt Cache Reorder: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x05) Offline data collection activity was aborted by an interrupting command from host. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 10) seconds. Offline data collection capabilities: (0x15) SMART execute Offline immediate. No Auto Offline data collection support. Abort Offline collection upon new command. No Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. No Selective Self-test supported. SMART capabilities: (0x0002) Does not save SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x00) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 10) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE 1 Raw_Read_Error_Rate PO---- 100 100 070 - 0 5 Reallocated_Sector_Ct PO---- 100 100 000 - 0 9 Power_On_Hours -O---- 100 100 000 - 1422 12 Power_Cycle_Count -O---- 100 100 000 - 2240 177 Wear_Leveling_Count PO---- 100 100 000 - 28378 178 Used_Rsvd_Blk_Cnt_Chip PO---- 100 100 000 - 21 181 Program_Fail_Cnt_Total PO---- 100 100 000 - 0 182 Erase_Fail_Count_Total PO---- 100 100 000 - 0 187 Reported_Uncorrect -O---- 100 100 000 - 49 192 Power-Off_Retract_Count PO---- 100 100 000 - 94 196 Reallocated_Event_Count PO---- 100 100 000 - 49 198 Offline_Uncorrectable PO---- 100 100 000 - 0 199 UDMA_CRC_Error_Count PO---- 100 100 000 - 28 232 Available_Reservd_Space PO---- 098 098 010 - 0 ||||||_ K auto-keep |||||__ C event count ||||___ R error rate |||____ S speed/performance ||_____ O updated online |______ P prefailure warning General Purpose Log Directory Version 0 SMART Log Directory Version 0 Address Access R/W Size Description 0x00 GPL,SL R/O 1 Log Directory 0x01 GPL,SL R/O 1 Summary SMART error log 0x06 GPL,SL R/O 1 SMART self-test log 0x07 GPL,SL R/O 1 Extended self-test log 0x10 GPL,SL R/O 1 SATA NCQ Queued Error log 0x11 GPL,SL R/O 1 SATA Phy Event Counters log 0x80-0x9f GPL,SL R/W 1 Host vendor specific log 0xe0 GPL,SL R/W 1 SCT Command/Status 0xe1 GPL,SL R/W 1 SCT Data Transfer SMART Extended Comprehensive Error Log (GP Log 0x03) not supported SMART Error Log Version: 1 Warning: ATA error count 0 inconsistent with error log pointer 1 ATA Error Count: 0 CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 0 occurred at disk power-on lifetime: 768 hours (32 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 53 00 00 01 01 30 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 53 00 00 00 01 01 30 00 40d+19:08:49.015 [RESERVED] 53 00 00 00 01 01 30 08 08:02:56.631 [RESERVED] 53 00 00 00 01 03 30 08 43d+09:22:11.063 [RESERVED] 53 00 00 00 01 02 30 08 42d+23:58:34.487 [RESERVED] 53 00 00 00 01 01 30 00 42d+14:30:35.767 [RESERVED] Error -3 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 00 00 00 00 00 00 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 00 03 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2] Error -4 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 00 01 00 00 00 00 01 Error: Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 00 40 00 00 00 00 00 a5 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2] 01 d6 00 00 00 00 01 22 7d+08:56:05.680 [RESERVED] 03 d4 00 00 00 00 01 1e 7d+08:56:05.680 CFA REQUEST EXTENDED ERROR 02 00 00 00 00 00 01 00 7d+08:56:05.680 [RESERVED] SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 35333 - # 2 Extended offline Completed without error 00% 35077 - # 3 Extended offline Completed: read failure 90% 34821 286295552 # 4 Extended offline Completed: read failure 90% 32773 284218368 # 5 Extended offline Completed: read failure 90% 32517 338552320 # 6 Extended offline Completed: read failure 90% 32261 283265536 # 7 Extended offline Completed without error 00% 31493 - # 8 Extended offline Completed without error 00% 31493 - # 9 Extended offline Completed: read failure 90% 31237 302961152 #10 Extended offline Completed: read failure 90% 31237 264429568 #11 Short offline Completed without error 00% 7424 - #12 Offline Completed: read failure 100% 30981 340627200 #13 Offline Completed: read failure 100% 28677 340627200 #14 Offline Completed: read failure 100% 28677 254952704 #15 Offline Completed: read failure 100% 28677 254952704 #16 Extended offline Completed without error 00% 56066 - #17 Extended offline Completed without error 00% 48386 - #18 Extended offline Completed without error 00% 47106 - #19 Extended offline Completed without error 00% 45570 - 10 of 10 failed self-tests are outdated by newer successful extended offline self-test # 1 Selective Self-tests/Logging not supported SCT Status Version: 3 SCT Version (vendor specific): 1 (0x0001) SCT Support Level: 1 Device State: Active (0) Current Temperature: ? Celsius Power Cycle Min/Max Temperature: ?/ ? Celsius Lifetime Min/Max Temperature: ?/ ? Celsius Under/Over Temperature Limit Count: 0/0 SCT Temperature History Version: 2 Temperature Sampling Period: 0 minutes Temperature Logging Interval: 0 minutes Min/Max recommended Temperature: ?/ ? Celsius Min/Max Temperature Limit: ?/ ? Celsius Temperature History Size (Index): 128 (0) Index Estimated Time Temperature Celsius 1 2015-12-22 14:12 ? - ... ..(126 skipped). .. - 0 2015-12-22 16:19 ? - SCT Error Recovery Control: Read: 2 (0,2 seconds) Write: 2 (0,2 seconds) Device Statistics (GP/SMART Log 0x04) not supported SATA Phy Event Counters (GP Log 0x11) ID Size Value Description 0x0001 2 0 Command failed due to ICRC error 0x0002 2 0 R_ERR response for data FIS 0x0003 2 0 R_ERR response for device-to-host data FIS 0x0004 2 0 R_ERR response for host-to-device data FIS 0x0005 2 0 R_ERR response for non-data FIS 0x0006 2 0 R_ERR response for device-to-host non-data FIS 0x0007 2 0 R_ERR response for host-to-device non-data FIS 0x0008 2 0 Device-to-host non-data FIS retries 0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy 0x000a 2 2 Device-to-host register FISes sent due to a COMRESET 0x000b 2 0 CRC errors within host-to-device FIS 0x000d 2 0 Non-CRC errors within host-to-device FIS 0x000f 2 0 R_ERR response for host-to-device data FIS, CRC 0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC 0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC 0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
------------------------------------------------------------------------------
_______________________________________________ Smartmontools-database mailing list Smartmontools-database@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/smartmontools-database