Hello, i've got some data to Add to the Database:

Description - Seagate Backup Plus Hub 8 TB Desktop
USB bridge - Unknown USB bridge
idVendor:idProduct (bcdDevice) - 0x0bc2:0xab38 (0x100)
Manufacturer / Product - Seagate / Backup Plus Hub
Option(s) - -d sat
Tested on - Linux
Author / Reference - Legodev
Comment - This case includes an Seagate Archive HDD ST8000AS0002-1NA17Z


Example Output:
smartctl --all /dev/sdb -d sat
smartctl 6.4 2015-06-04 r4109 [x86_64-linux-4.5.1-gentoo] (local build)
Copyright (C) 2002-15, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Archive HDD
Device Model:     ST8000AS0002-1NA17Z
Serial Number:    Z840WQHB
LU WWN Device Id: 5 000c50 0937b96ff
Firmware Version: RT17
User Capacity:    8,001,563,222,016 bytes [8.00 TB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5980 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is:    Tue Feb 14 14:45:00 2017 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                        was completed without error.
                                        Auto Offline Data Collection:
Enabled.
Self-test execution status:      (   0) The previous self-test routine
completed
                                        without error or no self-test
has ever
                                        been run.
Total time to complete Offline
data collection:                (    0) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection
on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 967) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x30b5) SCT Status supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE
UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   105   100   006    Pre-fail  Always
      -       8815184
  3 Spin_Up_Time            0x0003   093   093   000    Pre-fail  Always
      -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always
      -       8
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always
      -       0
  7 Seek_Error_Rate         0x000f   100   253   030    Pre-fail  Always
      -       1772
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always
      -       1
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always
      -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always
      -       8
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always
      -       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always
      -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always
      -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always
      -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always
      -       0
190 Airflow_Temperature_Cel 0x0022   062   062   045    Old_age   Always
      -       38 (Min/Max 13/38)
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always
      -       0
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always
      -       4
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always
      -       10
194 Temperature_Celsius     0x0022   038   040   000    Old_age   Always
      -       38 (0 13 0 0 0)
195 Hardware_ECC_Recovered  0x001a   105   100   000    Old_age   Always
      -       8815184
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always
      -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always
      -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age
Offline      -       0 (251 201 0)
241 Total_LBAs_Written      0x0000   100   253   000    Old_age
Offline      -       1149338
242 Total_LBAs_Read         0x0000   100   253   000    Old_age
Offline      -       6045439

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, SlashDot.org! http://sdm.link/slashdot
_______________________________________________
Smartmontools-database mailing list
Smartmontools-database@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/smartmontools-database

Reply via email to