Pekka,
I have been unsuccessful in identifying the problem in my SIPP scenario. I
was wondering if you could please take a look at it and see if you spot the
problem (it is. It is very simple. It sends an invite, waits for a 302
response and sends an ack. Thank you.
Jonathan
On Thu, Jan 29, 2
2009/1/26 jonathan augenstine :
> Ignore the first trace I sent you. It was incomplete as it overflowed the
> window buffer. I retested and the complete trace is below.
It seems to me that you have copy-pasted wrong ACK code to your SIPP
scenario. The RFC 3261 makes difference between ACK to 2XX
2009/1/25 jonathan augenstine :
> I have two issues that I am struggling with and need some input. The
> application I am developing receives an INVITE, does a database lookup, and
> redirects the INVITE using a 302 Temporarily Moved response. My first issue
> is the sending of a 100 TRYING messa