Hello Jorick,
We committed the new version (8.0.8.40) with some bugs fixed - both to CVS
and as tar.gz. It should be able to re-create default /etc/autocampars.xml
that will use internal trigger. This file is created when the
autocampars.php runs for the first time and the file does not exist. If
* Jan 1 00:01:03 Elphel353 kernel: 10359A did not respond after changing
10353 sensor clock frequency to 96MHz
*
Jorick,
This line shows that something is wrong. What cable (length) do you have
between 10353 and 10359? If it a long one - can you try a short one?
825 printk(10353 sensor
Dear Andrey/Oleg,
We disassembled the 359 and sensors and tested them all directly on the
camera and they all work ok. When can we use the new CVS code? I've seen
a lot of commits already :-)
Thank you for all your efforts as we know you guys are very busy with
the Eyesis and that's looking
Oleg,
Yes the log shows that the sensors were never triggered, but I would rather
zero out the TRIG_CONDITION parameter. The code I'm testing now
distinguishes between Eyesis mode and other 10359 applications and program
default /etc/autocampars.xml accordingly. For Eyesis camera will use
Hello Jorick,
The problem is known - we should not install the latest CVS software on
your camera, rather use the latest archive or image that is on sourceforge.
Lately we were actively developing 19359 code for Eyesis camera so spectific
code r4e
lated to Eyesis got to CVS. With this code when