Re: Exclude invalid sensors from the sensors MIB

2015-11-17 Thread Stuart Henderson
On 2015/11/17 11:47, Gerhard Roth wrote: > Sensors marked as invalid should be excluded by snmpd(8) from the sensors > MIB just as sysctl(8) excludes them from the 'hw.sensors' tree. Agreed - any OKs to commit? After: $ snmptable -v2c -c public 127.0.0.1 sensorTable SNMP table:

Re: Exclude invalid sensors from the sensors MIB

2015-11-17 Thread Sebastian Benoit
ok Stuart Henderson(st...@openbsd.org) on 2015.11.17 11:33:50 +: > On 2015/11/17 11:47, Gerhard Roth wrote: > > Sensors marked as invalid should be excluded by snmpd(8) from the sensors > > MIB just as sysctl(8) excludes them from the 'hw.sensors' tree. > > Agreed - any OKs to commit? > >

Exclude invalid sensors from the sensors MIB

2015-11-17 Thread Gerhard Roth
Sensors marked as invalid should be excluded by snmpd(8) from the sensors MIB just as sysctl(8) excludes them from the 'hw.sensors' tree. Gerhard Index: usr.sbin/snmpd/mib.c === RCS file: /cvs/src/usr.sbin/snmpd/mib.c,v retrieving