[therion] How to change settings for just a few readings?

2004-09-29 Thread Stacho Mudrak
The attached patch should enable group-endgroup inside centerline command. I have not tested it extensively, but you should be able to change everything (data order, calibration, sd, units etc.) inside. Regards, S. John Pybus wrote: > Stacho Mudrak wrote: > >> There is no problem to add

[therion] How to change settings for just a few readings?

2004-09-28 Thread Stacho Mudrak
OK, I'll put it on the top of TODO list - at least now it seems to be like a very simple thing to implement. Regards, S. John Pybus wrote: > Stacho Mudrak wrote: > >> There is no problem to add somethig like group-endgroup pair inside >> centerline, if it will really help you (or I can use

[therion] How to change settings for just a few readings?

2004-09-28 Thread John Pybus
Stacho Mudrak wrote: > There is no problem to add somethig like group-endgroup pair inside > centerline, if it will really help you (or I can use just begin-end pair if > you wish). > > Then it could be rewritten this way: > > centreline > calibrate tape 1 > 1 2 10 0 0 > group >

[therion] How to change settings for just a few readings?

2004-09-28 Thread Stacho Mudrak
Olly Betts wrote: > The only solution I can see is to track which settings are in effect and > reset them all after the *end. That's just about OK for automated > conversion if nobody's going to want to edit the result, but it must be > a right headache for anyone who has tried to hand convert a

[therion] How to change settings for just a few readings?

2004-09-28 Thread John Pybus
Stacho Mudrak wrote: > No, there is no such possibility. You have to repeat calibration every time > it changes. I would rewrite your example this way: > > encoding iso8859-1 > survey test -title "test" > centreline > calibrate tape 1 > 1 2 10 0 0 > calibrate tape 2

[therion] How to change settings for just a few readings?

2004-09-28 Thread Olly Betts
On Tue, Sep 28, 2004 at 12:29:51PM +0200, Stacho Mudrak wrote: >> Olly Betts wrote: >> > >>> >The only solution I can see is to track which settings are in effect and >>> >reset them all after the *end. That's just about OK for automated >>> >conversion if nobody's going to want to edit the

How to change settings for just a few readings?

2004-09-27 Thread Olly Betts
I'm looking at how to convert from .svx format to .th format. Mostly working, except I can't see how to handle this cleanly (the situation modelled here is that the tape is too short, and for one leg is was measured from a different point - in the example this was distilled from because 2-3 was a