[time-nuts] 5087A Distribution Amplifier

2007-05-02 Thread Brian Kirby
I bought an HP 5087A distribution amplifier off of ebay. The unit is in good working condition. Funny the power supply is putting out 120 hertz square waves.which makes all the outputs look like they are oscillating garbagedisconnecting the power supply from the load does not change

Re: [time-nuts] 5087A Distribution Amplifier

2007-05-02 Thread Brian Kirby
Your a life saver. Can you confirm the pass transistor part number and the regulator IC, looks like the 723 ? Dr Bruce Griffiths wrote: Brian Kirby wrote: I bought an HP 5087A distribution amplifier off of ebay. The unit is in good working condition. Funny the power supply is putting out

Re: [time-nuts] 5087A Distribution Amplifier

2007-05-02 Thread Jean-Louis Oneto
Message - From: Brian Kirby [EMAIL PROTECTED] To: Time Nuts time-nuts@febo.com Sent: Wednesday, May 02, 2007 9:54 PM Subject: [time-nuts] 5087A Distribution Amplifier I bought an HP 5087A distribution amplifier off of ebay. The unit is in good working condition. Funny the power supply

Re: [time-nuts] 5087A Distribution Amplifier

2007-05-02 Thread Dr Bruce Griffiths
Brian Kirby wrote: Your a life saver. Can you confirm the pass transistor part number and the regulator IC, looks like the 723 ? Brian Regulator is a 723, Transistor Q1 is a 2N3054. Bruce ___ time-nuts mailing list time-nuts@febo.com

Re: [time-nuts] 5087A Distribution Amplifier

2007-05-02 Thread Brian Kirby
- 06130 Grasse - France Tel: (+33)[0]493.40.53.80, Fax: (+33)[0]493.40.53.33 e-mail: [EMAIL PROTECTED] - Original Message - From: Brian Kirby [EMAIL PROTECTED] To: Time Nuts time-nuts@febo.com Sent: Wednesday, May 02, 2007 9:54 PM Subject: [time-nuts] 5087A Distribution Amplifier

Re: [time-nuts] 5087A Distribution Amplifier

2007-05-02 Thread Mike Feher
: [time-nuts] 5087A Distribution Amplifier Hi Brian! Last time I had this problem, it was the VERY BIG capacitor (1500MFD - 40VDC) which measured as 21.8pF (yes PicoFarad!!!) Jean-Louis Oneto OCA GEMINI - Avenue Copernic - 06130 Grasse - France Tel: (+33)[0]493.40.53.80, Fax: (+33)[0]493.40.53.33 e-mail