My trusted 58503B displays strange values, this suddenly started a couple of
weeks ago.
TI values used to be within +- 50ns, now the monitoring software shows
values going between +- 500 ns!
What could be the reason for this? I replaced the internal UT+ GPS receiver,
same results.
Any
Have you another GPSDO with a PPS output? If not then try to connect the
PPS output of the UT+ and the 58503 PPS output to a dual trace 'scope with
persistence, trig on the UT+ and see the total span of the 58503 PPS.
On Wed, Jul 25, 2012 at 10:59 AM, nde n...@hispeed.ch wrote:
My trusted