Thanks Mike, that worked a treat- and next time, I will read the help
file in a bit more detail- I completely missed that one!
On Sat, Jun 2, 2012 at 7:07 PM, mike cook wrote:
> Le 02/06/2012 09:22, ken johnson a écrit :
>>
>> Hi, can someone please tell me how to get the satellite graphic plot
>
Le 02/06/2012 09:22, ken johnson a écrit :
Hi, can someone please tell me how to get the satellite graphic plot
up on lady heather by using command line switches at program start?
If I enter s then 3 when the program is running I get some displays
up, but when I try to add the commands to the sta
Hi, can someone please tell me how to get the satellite graphic plot
up on lady heather by using command line switches at program start?
If I enter s then 3 when the program is running I get some displays
up, but when I try to add the commands to the startup it gives me the
help text. I have tried
Hello John,
Thanks for the tip,
I did not add the space between the switches, and I did not add the = sign.
The example you posted on the readme file was difficult for me to read.
I shall try the correct syntax later this morning after a caffeine break.
Suggestion for Mark, How about some indi
Got up too early this morning, no caffeine yet
note correction.
Stan W1LE wrote:
> You tried
>
> 'C:Program Files\Heather\heather.exe /mp[=5]'
>
> Try
>
> "C:\Heather\heather.exe" /mp5
>
Need to add the directory for the Program Files
try"C:\Program Files\Heather\heather.exe" /m
Hmm. Are you following the example shown in the readme file? What is the
exact command line you're using where multiple options aren't working?
I normally use
"C:\Heather\heather.exe" /i=10 /mt=130
... myself.
-- john, KE5FX
> But, I have been unable to get more than one switch to w
You tried
'C:Program Files\Heather\heather.exe /mp[=5]'
Try
"C:\Heather\heather.exe" /mp5
But, I have been unable to get more than one switch to work, the first in line..
We need clarification on the exact syntax to use for multiple command line
switches.
Stan, W1LE
Michael Bake
Yes, it would be nice to be able to load the log file and resume from that
position, but what about the gap between when you stopped logging and
restarted? That would destroy the integrity of the OADEV/ADEV numbers. You
could just ignore the gap in the graphs, but the OADEV numbers would
If someone is taking suggestions, I just thought it would be nice if I could
get 9 values for the accumulated amount of time spent receiving N
satellites, where N goes from 0 to 8. (Or more, for newer T-Bolts.) Seems
like it would be useful for evaluating and comparing the quality of antenna
site
Sent: Wednesday, February 18, 2009 6:01 PM
> To: Discussion of precise time and frequency measurement
> Cc: John Miles
> Subject: Re: [time-nuts] Lady Heather command line modification
> question...
>
>
> John,
>
> I just started playing around with Lady Heather (for
John,
I just started playing around with Lady Heather (for some reason, that
sounds kinky :-) )
Any chance of adding the ability to read from the log file when
starting, so the graphs/stats can be recovered from a log? And
optionally, continue collecting/adding data to that log, as might be
d
The parameters need to be outside the quotes, or they're considered part of
the executable filename itself. (When I posted the latest version the other
day, I added an example -- see http://www.ke5fx.com/heather/readme.htm and
click on the small image of the shortcut dialog.)
-- john, KE5FX
> T
Mike,
Put the qualifier goes after the last quote. Here is how I specify
that COM2 is to be used: "C:\Program Files\Heather\heather.exe" /2
Ken, WA2LBI
On Wed, Feb 18, 2009 at 19:45, Michael Baker wrote:
.
.
.
> I am trying to change the scale for the PPS graph from 2ns/div
> to 5ns/div and th
Hello, John--
Every now and then, LH says my T-bolt PPS and DAC are experiencing
wide excursions. The PPS OADEV and the OSC OADEV both stay down
around 6 X e-13 but PPS and DAC both get hinky for an hour or two
and then things settle back down for a few hours. This process
seems to repeat itself
14 matches