Re: [time-nuts] NEO-7 GPS default 1pps width?

2018-04-08 Thread Leo Bodnar
Yes, that's exactly how Ublox default PPS setting works.
Pulse is positive - rising edge is "the time."
Leo

On 8 Apr 2018, at 17:00, time-nuts-requ...@febo.com wrote:

> The manual says pulseLenRatio is zero and pulseLenRatioLock is 100,000 (us)
> flags-lockedOtherSet is 1, so I think that means "only generate 100ms 
> pulses when locked"
> 
> Does that align with anyone else's experience?

___
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.


Re: [time-nuts] NEO-7 GPS default 1pps width?

2018-04-08 Thread Mike Cook

I have 6M and 8M and they are both 100ms 1PPS signals. Interpolate.

> Le 8 avr. 2018 à 15:51, jimlux  a écrit :
> 
> I've got some NEO-7Ms here, and without an oscilloscope handy - what's the 
> factory default 1pps pulse width?
> 
> The manual says pulseLenRatio is zero and pulseLenRatioLock is 100,000 (us)
> flags-lockedOtherSet is 1, so I think that means "only generate 100ms pulses 
> when locked"
> 
> 
> Does that align with anyone else's experience?
> 
> Tnx
> Jim
> ___
> time-nuts mailing list -- time-nuts@febo.com
> To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
> and follow the instructions there.

Don’t worry about how powerful the machines are. Worry about who the machines 
are giving  power to.

___
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.