Re: Topband: twisted house wiring

2017-02-22 Thread K1FZ-Bruce
As I remember it from an electrician that married a 2nd time to my Aunt. hi. The ground lost its connection and the coiled wrapper became hot like a "hot plate" carrying the current.I was about 10 years old then and just wondering how a radio worked. 73 Bruce-k1fz On Wed, 22 Feb 2017

Re: Topband: twisted house wiring

2017-02-22 Thread Brian Pease
I installed a vanity in a old house in New London, CT. The BX only had 2 wires for the original light & 2-prong outlet. Fortunately the jacket was grounded although it had never been connected to the old fixture. I needed the ground for the new GFI outlet. On 2/22/2017 5:06 PM, MICHAEL ST

Re: Topband: twisted house wiring

2017-02-22 Thread MICHAEL ST ANGELO
BX cable is still required in New York City. I had to use it when I lived in Queens. How did the metal wrapper get hot? Was current passing througgh it? The BX I had included a ground wire; maybe the earlier BX used the wrapper as the ground. Mike N2MS > On February 22, 2017 at 3:45 PM

Topband: twisted house wiring

2017-02-22 Thread K1FZ-Bruce
Live near a housing development with many tenants. The high line on the road is about 20 feet diagonally from my attic. Getting a lot of noise even with my house main breaker off. Appears to be induced into the attic wiring. Question. Anyone tried some form "twisted pair with green wire"