Thanks; this was a really helpful reply; when the electricity goes off, one
tends to check one's own plug rather than think the main transformer just died.
Especially the capacity/latency part; I would never have gotten that by myself.
Sent with ProtonMail Secure Email.
‐‐‐ Original Me
On 14.03.2018 03:56, teor wrote:
On 13 Mar 2018, at 20:51, mytormail wrote:
I just doesn't feel right if donated capacity isn't used.
Oh, but your relay's spare capacity *is* used.
Just not the way you think.
Hi teor,
Thanks for your reassuring words. :)
I just wait a few weeks and see w
> On 13 Mar 2018, at 20:51, mytormail wrote:
>
> I just doesn't feel right if donated capacity isn't used.
Oh, but your relay's spare capacity *is* used.
Just not the way you think.
A congested relay is a slow and unstable relay.
A relay with extra capacity has lower latency, and can deal wit
Yes, I have experienced the same thing; my throughput is slower as well. Not
only have I dropped from about 2,000 connexions to 1, 000; my rate has gone
down as well:
#vnstat -d
02/21/201816.83 GiB | 16.59 GiB | 33.42 GiB |3.24 Mbit/s
02/22/201818.73 GiB | 18.49
Hi,
I am curious if your relay is back on speed now.
I experience the same thing. Since the latest update my two "fast"
relay's (around 5100KB) have now dropped to half the speed and seem to
go slower as time goes by. Processor is hardly used, memory is no issue,
logs seem okay. My other two r
Hello,
On 11 March 2018 at 22:02, wrote:
> Thanks, Gary; I was just wondering, since I think of mine as a typical
> small relay, and wondered if others had noticed the same differences.
>
>
Before December, my accountingmax was 3GB, I had to increase it to 8GB stop
it from hibernating midday. No
Thanks, Gary; I was just wondering, since I think of mine as a typical small
relay, and wondered if others had noticed the same differences.
Sent with [ProtonMail](https://protonmail.com) Secure Email.
‐‐‐ Original Message ‐‐‐
On March 11, 2018 6:52 AM, Gary wrote:
> Hello
>
> On 11 Ma
Hello
On 11 March 2018 at 02:50, wrote:
> Dear All,
> On March 5 I changed to the newest version 3.2.10 on a middle relay I
> run. I went away for a few days, checked today, and found that my traffic
> is down, and my connexions, which were around 2,000 since December, are now
> about 1,000. C
Dear All,
On March 5 I changed to the newest version 3.2.10 on a middle relay I run. I
went away for a few days, checked today, and found that my traffic is down, and
my connexions, which were around 2,000 since December, are now about 1,000.
Consensus weight is still the same (about 450) as i