Bug description:
  Steps to reproduce:

   1) On a touch device, browse to 
http://blogs.sitepointstatic.com/examples/tech/full-screen/index2.html and tap 
on the squirrel to make it go fullscreen
   2) Pull down the indicators bar (partially or completely)

  Expected result: the browser (when loosing active focus) exits
  fullscreen mode

  Current result: it doesn’t exit fullscreen mode.

  This works as expected in OTA-14 (the latest stable image as of this
  writing) but not in rc-proposed, and the most likely change that would
  have introduced this regression is support for multiple windows:
  https://bazaar.launchpad.net/~phablet-team/webbrowser-
  app/trunk/revision/1536.