I´m curious about something, you have the constant WH_MAX_MSG = 100, which
means that each Handler created can handle up to 100 different messages,
from different objects right?
Is there a reason to be 100? If I increase this number to 200 for example,
will I be able to create the double amount of sockets? Since, the most
limiting fact is the handle (10.000 handlers on the process), if I share 1
handle with more classes, theorically I can create many more sockets
You are right. The only issue is that a given handle correspond to a single
message queue. Having too much component per handle could result in a
message queue growing too much and possibly being overflown (Never saw
that).
If you need a large number of sockets because you have a large number of
connection, this is not aproblem as long as most of the connections are not
very active. This is probably the case otherwise you'd have a CPU problem.
--