Hello,
I just 'fixed' a VERY strange V6 component behavior in a multi-threaded
server application that drove me nuts over the last hours >8-|
V6 worked great, however I simply forgot that messages in the range
of WM_USER up to WM_USER + OverbyteIcsWndControl.WH_MAX_MSG
are now reserved for use wi
This make me thinking we could define the messages using the highest number
first and then going low. This would eliminate most clashes as many
applications start from WM_USER and goes up. Easy change to do.
--
Contribute to the SSL Effort. Visit http://www.overbyte.be/eng/ssl.html
--
[EMAIL PRO
I do agree. I already use v6 (old beta) but had no problem with the user
messages, using the latest beta without your proposal would break my app.
- Original Message -
From: "Francois PIETTE" <[EMAIL PROTECTED]>
To: "ICS support mailing"
Sent: Tuesday, June 20, 2006 8:12 PM
Subject: Re:
So the question is: what is the best highest number to use ?
Borland is already using messages starting from $B000 and $BC00 (See
Controls.pas).
--
[EMAIL PROTECTED]
http://www.overbyte.be
- Original Message -
From: "Frans van Daalen" <[EMAIL PROTECTED]>
To: "ICS support mailing"
Sent: