Hi Andrew,
On Mar 24, 2014, at 9:40 AM, Andrew Gabbasov wrote:
Calculation of the timeout value should be based on actual clock value,
written to controller registers. Since mmc-tran_speed is either the
maximum allowed speed, or the preliminary value, that is be not yet
set to registers, the
Calculation of the timeout value should be based on actual clock value,
written to controller registers. Since mmc-tran_speed is either the
maximum allowed speed, or the preliminary value, that is be not yet
set to registers, the actual timeout, taken by the controller, based
on its clock