On Wed, 7 Mar 2018 22:08:24 +0100
Alexander Graf wrote:
> After the UART was initialized, we may still have bogus data in the
> RX queue if it was enabled with incorrect pin muxing before.
>
> So let's flush the RX queue whenever we initialize baud rates.
>
> This fixes a regression with the dy
On Wed, Mar 7, 2018 at 9:08 PM, Alexander Graf wrote:
> After the UART was initialized, we may still have bogus data in the
> RX queue if it was enabled with incorrect pin muxing before.
>
> So let's flush the RX queue whenever we initialize baud rates.
>
> This fixes a regression with the dynamic
After the UART was initialized, we may still have bogus data in the
RX queue if it was enabled with incorrect pin muxing before.
So let's flush the RX queue whenever we initialize baud rates.
This fixes a regression with the dynamic pinmuxing code when enable_uart=1
is not set in config.txt.
Fix
3 matches
Mail list logo