If you call !SET.PTR with the print channel set to -2-ABS(printchannel)
UniVerse will return the SETPTR settings.
---
u2-users mailing list
u2-users@listserver.u2ug.org
To unsubscribe please visit http://listserver.u2ug.org/
Is there a way to get the values reported by SETPTR, especially the
destination without parsing the results of the ECL command?
If you're on UniData, take a look at the UniBasic GETPU() and GETPTR()
functions.
Tim Snyder
Consulting I/T Specialist
U2 Lab Services
Information Management, IBM
Hi Jonathan,
Is there a way to get the values reported by SETPTR, especially the
destination without parsing the results of the ECL command?
Take a look at the !GETPU() subroutine.
Martin Phillips
Ladybridge Systems Ltd
17b Coldstream Lane, Hardingstone, Northampton, NN4 6DB
Does !SETPTR (or !SET.PTR - can't remember) do what you want?
Cheers,
Wol
-Original Message-
From: Jonathan Leckie [mailto:[EMAIL PROTECTED]
Sent: 10 August 2007 09:55
To: u2-users@listserver.u2ug.org
Subject: [U2] Getting current SETPTR values
Is there a way to get the values reported