I think that would be the second best solution, after fixing KVM.
But if it's as hard and nearly impossible as you said I think it would be
better to include a GUI to manually change the resolution.
--
Incomplete monitor specification data for Sony CPD-E200 due to KVM switch
interfering with
That sounds like a perfectly valid solution, Bryce. Thanks for following up.
--
Incomplete monitor specification data for Sony CPD-E200 due to KVM switch
interfering with EDID data collection
https://bugs.launchpad.net/bugs/180601
You received this bug notification because you are a member of
FactTech,
Well, the fact that KVM's sometimes squelch EDID has been a well known
issue for a long long time. As you mentioned, there is no known
solution that can be applied automatically. So for this particular
issue I believe we're at a dead end.
However, for this use case, others have
** Changed in: xorg-server (Ubuntu)
Sourcepackagename: xorg = xorg-server
Status: Incomplete = Confirmed
--
Incomplete monitor specification data for Sony CPD-E200 due to KVM switch
interfering with EDID data collection
https://bugs.launchpad.net/bugs/180601
You received this bug
I am using Ubuntu 8.10, I applied those changes and the results havent
changed. I have read on several forums that the conf file is no longer being
actively utilized at boot.
--
Incomplete monitor specification data for Sony CPD-E200 due to KVM switch
interfering with EDID data collection
Also I don't have a KVM switch, this is a stand alone 19 monitor.
--
Incomplete monitor specification data for Sony CPD-E200 due to KVM switch
interfering with EDID data collection
https://bugs.launchpad.net/bugs/180601
You received this bug notification because you are a member of Ubuntu
Bugs,
sphacelate,
You might do the following to see if EDID detection is working
correctly:
1) download the read-edid package from the repository ('sudo apt-get install
read-edid')
2) check that EDID data can be captured from your monitor ('sudo get-edid |
parse-edid')
If EDID data is captured
** Summary changed:
- Incomplete monitor specification data for Sony CPD-E200
+ Incomplete monitor specification data for Sony CPD-E200 due to KVM switch
interfering with EDID data collection
** Description changed:
- The automatic configuration for a Sony Multiscan E200 (model #CPD-E200)
-
For anyone reading this issue, the cause has ultimately been determined to be
the fact that a Belkin Omniview KVM switch interferes with the collection of
EDID data for the monitor. There is no known solution to the EDID detection
issue, which is a hardware problem outside of the control of