This bug was fixed in the package linux - 4.10.0-26.30
---
linux (4.10.0-26.30) zesty; urgency=low
* linux: 4.10.0-26.30 -proposed tracker (LP: #1700528)
* CVE-2017-1000364
- Revert "UBUNTU: SAUCE: mm: Only expand stack if guard area is hit"
- Revert "mm: do not collapse
This bug was fixed in the package linux - 4.10.0-26.30
---
linux (4.10.0-26.30) zesty; urgency=low
* linux: 4.10.0-26.30 -proposed tracker (LP: #1700528)
* CVE-2017-1000364
- Revert "UBUNTU: SAUCE: mm: Only expand stack if guard area is hit"
- Revert "mm: do not collapse
Sorry for the delays. The nvme fio test didn't stress the system enough
with this build, so I setup two systems with a direct wired, back to
back, high performance network link and ran iperf. With the client in
pass through, and the server in passthough/nonpassthrough, the data rate
was slightly
This bug is awaiting verification that the kernel in -proposed solves
the problem. Please test the kernel and update this bug with the
results. If the problem is solved, change the tag 'verification-needed-
zesty' to 'verification-done-zesty'. If the problem still exists, change
the tag
** Changed in: linux (Ubuntu Zesty)
Status: New => Fix Committed
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1688158
Title:
[SRU][Zesty] Support SMMU passthrough using the default domain
** Also affects: linux (Ubuntu Zesty)
Importance: Undecided
Status: New
** Changed in: linux (Ubuntu)
Status: Incomplete => Fix Committed
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
Re-test boot on Power8 from PPA.
ubuntu@manjo-srutest:~$ uname -a
Linux manjo-srutest 4.10.0-21-generic #23~sru4.test4-Ubuntu SMP Tue May 30
21:03:42 UTC 2017 ppc64le ppc64le ppc64le GNU/Linux
ubuntu@manjo-srutest:~$
--
You received this bug notification because you are a member of Ubuntu
Re-tested boot on ARM Centriq platform from the PPA.
ubuntu@ubuntu:~$ uname -a
Linux ubuntu 4.10.0-21-generic #23~sru4.test4-Ubuntu SMP Tue May 30 21:04:32
UTC 2017 aarch64 aarch64 aarch64 GNU/Linux
ubuntu@ubuntu:~$
--
You received this bug notification because you are a member of Ubuntu
Bugs,
This patch was applied on top of the patch series to implement smmu pass though
on zesty kernel and tested on Dell PowerEdge T710 and it fixes the regression.
ubuntu@adib:~$ uname -a
Linux adib 4.10.0-21-generic #23~sru4.test5 SMP Tue May 30 18:25:49 UTC 2017
x86_64 x86_64 x86_64 GNU/Linux
This is fixed in upstream by patch, will cherry-pick this patch and test
on intel system to fix this regression, and resubmit the sru.
commit 0ef7b235aeddf9b2f78889c7823a24745ebf0cf7
Author: Andy Shevchenko
Date: Wed Feb 15 16:42:21 2017 +0200
I get a kernel panic on AMD64 system .. investigating.
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1688158
Title:
[SRU][Zesty] Support SMMU passthrough using the default domain
To manage
Tested on Power8
ubuntu@manjo-srutest:~$ uname -a
Linux manjo-srutest 4.10.0-22-generic #24~sru4+test.1-Ubuntu SMP Wed May 24
18:42:19 UTC 2017 ppc64le ppc64le ppc64le GNU/Linux
ubuntu@manjo-srutest:~$
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is
Boot tested on Thunder-X no regressions.
Loading Linux 4.10.0-20-generic ...
Loading initial ramdisk ...
Ds1337GetDatetime Error Getting TimeEFI stub: Booting Linux Kernel...
EFI stub: EFI_RNG_PROTOCOL unavailable, no randomness supplied
EFI stub: Using DTB from configuration table
EFI stub:
** Tags added: qdf2400
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1688158
Title:
[SRU][Zesty] Support SMMU passthrough using the default domain
To manage notifications about this bug go to:
** Description changed:
[Impact]
Have the SMMU come up in a passthrough configuration, and then allow
subsequent translation for things such as VFIO. Rather than do this in each
SMMU driver, it's much cleaner to allow the default domain to be configured to
be something other than DMA.
** Description changed:
[Impact]
- Have the SMMU come up in a passthrough configuration, and then allow
subsequent translation for
- things such as VFIO. Rather than do this in each SMMU driver, it's much
cleaner to allow the default domain to be configured to be something other than
DMA.
+
** Description changed:
[Impact]
Have the SMMU come up in a passthrough configuration, and then allow
subsequent translation for
things such as VFIO. Rather than do this in each SMMU driver, it's much
cleaner to allow the default domain to be configured to be something other than
DMA.
17 matches