Public bug reported:
When running rsync on a directory of a few hundred files from rsync
3.0.9-4 on Ubuntu 13.04 Raring to rsync 3.1.0-2 on Ubuntu 14.04 Trusty
rsync errors with:
rsync error: error in rsync protocol data stream (code 12) at io.c(441)
[sender=3.0.9]
Here is the full command I'm
Public bug reported:
During automatic security updates our SSH broke and started segfaulting.
There was nothing waiting to install. We assumed broken dependencies so,
as it was behind, have done a do-release-upgrade, but it's failed here
as well.
ProblemType: Package
DistroRelease: Ubuntu 13.04
Here is the console log. I've stripped out the updating and downloading
sections:
$ sudo apt-get update sudo apt-get install bacula-director-mysql
[..]
The following packages were automatically installed and are no longer required:
linux-headers-3.2.0-23-generic
Public bug reported:
When installing bacula-director-mysql the package tried to configure
it's username and DB in MySQL before mysql-server has finished setting
itself up and started. Runs fine on second retry.
ProblemType: Bug
DistroRelease: Ubuntu 12.04
Package: bacula-director-mysql
Public bug reported:
When installing the meta package bacula-server it will reach the point
of configuring the database for bacula-director-mysql with dbconfig-
common before mysql-server has installed and started. The only way out
is to opt out of the automatic database installation and install
Workaround is to run `dpkg-reconfigure bacula-director-mysql` after
installation.
--
You received this bug notification because you are a member of Ubuntu
Server Team, which is subscribed to bacula in Ubuntu.
https://bugs.launchpad.net/bugs/1116634
Title:
bacula-server installation runs