Re: Could not retrieve the redirect address - No REST endpoint has been started

2018-09-25 Thread PedroMrChaves
Hello, Thank you for the reply. The problem sometimes happens when there is a jobmanager failover. I've attached the jobmanager logs for further debugging. flink-flink-jobmanager-1-demchcep00-01.log

Re: Could not retrieve the redirect address - No REST endpoint has been started

2018-08-03 Thread Till Rohrmann
Hi Pedro, it looks as if Flink could not start the WebRuntimeMonitor. Could you maybe share the jobmanager.log of the newly started JobManager which has no WebRuntimeMonitor started with us? Maybe there is a port conflict. Cheers, Till On Thu, Aug 2, 2018 at 11:35 AM vino yang wrote: > Hi

Re: Could not retrieve the redirect address - No REST endpoint has been started

2018-08-02 Thread vino yang
Hi Pedro, It sounds like a bug from Flink itself. You can create an issue in JIAR and give enough information, such as logs, completed exceptions, Flink versions, and your usage environment. Thanks, vino. 2018-08-02 16:45 GMT+08:00 PedroMrChaves : > Hello, > > It happens whether the WEB UI is

Re: Could not retrieve the redirect address - No REST endpoint has been started

2018-08-02 Thread PedroMrChaves
Hello, It happens whether the WEB UI is opened or not and it no longer works. When this happens I have to restart the job managers. regards, Pedro. - Best Regards, Pedro Chaves -- Sent from: http://apache-flink-user-mailing-list-archive.2336050.n4.nabble.com/

Re: Could not retrieve the redirect address - No REST endpoint has been started

2018-08-01 Thread Andrey Zagrebin
Hi Pedro, when you restart the cluster, do you keep Web UI open? and does Web UI work eventually after restart and getting this error? Cheers, Andrey > On 1 Aug 2018, at 11:56, PedroMrChaves wrote: > > Hello, > > I have a running standalone Flink cluster with 2 task managers and 2 job >