Re: Re: Cannot connect the ignite server after running one or two days

2018-02-01 Thread xiang jie
OK. I’ll try it when the problem appears next time. Thanks. 发件人: Evgenii Zhuravlev [mailto:e.zhuravlev...@gmail.com] 发送时间: 2018年2月1日 16:13 收件人: user@ignite.apache.org 主题: Re: 答复: Re: Cannot connect the ignite server after running one or two days " Failed to deserialize o

Re: 答复: Re: Cannot connect the ignite server after running one or two days

2018-02-01 Thread Evgenii Zhuravlev
> at > org.apache.ignite.marshaller.jdk.JdkMarshaller.unmarshal0( > JdkMarshaller.java > :119) > ... 4 more > > -邮件原件- > 发件人: ezhuravlev [mailto:e.zhuravlev...@gmail.com] > 发送时间: 2018年1月31日 21:50 > 收件人: user@ignite.apache.org > 主题: Re: Re:

答复: Re: Cannot connect the ignite server after running one or two days

2018-02-01 Thread xiang jie
21:50 收件人: user@ignite.apache.org 主题: Re: Re: Cannot connect the ignite server after running one or two days >There are several clients connected by VPN, is it possible to the client's restart regularly causing ignite socket communication to a certain degree of obstruction and becoming

Re: Re: Cannot connect the ignite server after running one or two days

2018-01-31 Thread ezhuravlev
>There are several clients connected by VPN, is it possible to the client's restart regularly causing ignite socket communication to a certain degree of obstruction and becoming more and more serious as time goes by? Does this mean that it's impossible to connect from server to client nodes

Re: Re: Cannot connect the ignite server after running one or two days

2018-01-30 Thread xiang jie
of obstruction and becoming more and more serious as time goes by? Thanks -邮件原件- 发件人: ezhuravlev [mailto:e.zhuravlev...@gmail.com] 发送时间: 2018年1月30日 23:00 收件人: user@ignite.apache.org 主题: Re: Re: Cannot connect the ignite server after running one or two days Hi, Looks like logs from the server

Re: Re: Cannot connect the ignite server after running one or two days

2018-01-30 Thread ezhuravlev
Hi, Looks like logs from the server is still not full. If you've checked them and you sure that you don't have any exceptions in it before witnessing this problem, then, I think that you could have some connection problems or a long GC pause. Do you have any network monitoring? Also, I would

Re: Cannot connect the ignite server after running one or two days

2018-01-23 Thread Evgenii Zhuravlev
Hi, I see that you use both ipv4 and ipv6 stacks, I think it can somehow affect this behavior, so, I would recommend enabling -Djava.net.preferIPv4Stack=true for all nodes in the cluster(including clients). Also, why do you decided to set such parameters to the communicationSPI:

Cannot connect the ignite server after running one or two days

2018-01-22 Thread xiang jie
Hi, We have deployed ignite 2.3 and created about 100 caches and load data from oracle into these caches. But clients(started in developing tomcat web apps, we often start and stop these apps) often cannot connect the ignite server after one or two days. By searching logs, we found below