Hey Antoine,
sounds like a bug to me. can you click on
github.com/apache/cloudstack/issues/new ;) ?
On Fri, Feb 2, 2024 at 10:48 PM Antoine Boucher wrote:
>
> In ACS version 4.18.1, when conducting a VM Primary Storage Migration, should
> the list of potential destinations exclude any Primary S
ence.
>
> Regards,
> Alex
>
>
>
>
> -Original Message-
> From: Alessandro Caviglione
> Sent: 07 May 2021 10:50
> To: users@cloudstack.apache.org
> Subject: Re: Primary storage migration
>
> Thank you Alex,
> iscsi subnet is present on same swit
7;s just my preferred one based on experience.
Regards,
Alex
-Original Message-
From: Alessandro Caviglione
Sent: 07 May 2021 10:50
To: users@cloudstack.apache.org
Subject: Re: Primary storage migration
Thank you Alex,
iscsi subnet is present on same switch fabric so we can add it,
Thank you Alex,
iscsi subnet is present on same switch fabric so we can add it, but since
xenserver port are actually in ACCESS with specific VLAN, how can I add an
IP with a tagged VLAN on xenserver?
On Fri, May 7, 2021 at 10:29 AM Alex Mattioli
wrote:
> Hi Alessandro,
>
> Is the new iSCSI subn
Hi Alessandro,
Is the new iSCSI subnet present in the same L2 switching fabric? In that case
you just need a VLAN interface on the 10.0.0.x network. If it is in a separate
switching fabric then you can add a couple extra NICs to your host and connect
to that network.