Hi list,


The TRex traffic generator's folks recommended us to contact you for an issue 
that might relate to DPDK virtio driver 
(https://groups.google.com/forum/#!topic/trex-tgn/LxtTV7G43AE).



Specifically, our scenario involves running TRex inside a KVM instance with 2 
vhost-user ports, which are connected in loopback mode via an OVS-DPDK (i.e. 
whatever sent through port1 goes to port2, and vice versa). We observe that the 
received traffic volume reported by TRex is much less than the transmitted (it 
is constantly 4B per packet), whereas:

1) the count of the received packets is the same

2) the contents of the received packets, as captured _inside_ the VM, are the 
same with the transmitted



Specifically, we experimented with different packet sizes being transmitted, 
i.e. 64B, 150B, 1000B, yet in the receive path the reported incoming volume 
corresponded constantly to 4B-per-packet, for all cases.



The TRex engineers suggested that it seems like an RX counters issues in virtio 
driver.



Experimental setup:

- TRex v2.45 (uses DPDK 17.11 AFAIK), within a QEMU v2.12

- on the host: OVS 2.10.0 with DPDK 17.11.3



Thanks,

Nikos







Reply via email to