configuration issues with Siemens MC35i

2008-02-07 Thread Peter Salvage
INFO: AT2[/dev/ttyUSB0]: speed set to 57600 [...] the last few lines keep repeating, with decreasing speeds to 9600, then it starts again at 115200. I'm tearing my hair out here - can someone point out what is obviously a glaring error in my config's above? Many thanks in anticipation Peter

Re: configuration issues with Siemens MC35i

2008-02-07 Thread Peter Salvage
, Tommi Peter Salvage kirjoitti: Hi all I've tried searching the archives and found lots of useful info but I'm not having success. I'm running 1.4.0 on Debian Here's part of my kannel.conf: group = core admin-port = 13000 admin-password = blah admin-allow-ip = 127.0.0.1 log-file = /tmp

Re: configuration issues with Siemens MC35i - SOLVED!

2008-02-07 Thread Peter Salvage
'scientists'? I meant Irish people. Message: 1 Date: Thu, 07 Feb 2008 13:19:06 +0200 From: Peter Salvage [EMAIL PROTECTED] Subject: To: users@kannel.org Message-ID: [EMAIL PROTECTED] Content-Type: text/plain; charset=ISO-8859-1; format=flowed Hi all I've tried searching the archives and found lots