Dear Jayraj Anadani, 

Thank you for your reply. As far as I have understood there are several ways to 
keep the electron wave functions close to the Born-Oppenheimer surface. One of 
them is as you are doing by, electron dynamics = "cg". Another one is the 
ensemble-DFT approach. I have put my questions for the ensemble-DFT approach 
under the topic, Ensemble_DFT simulation. Ensemble-DFT also does 
cg-minimization of electron wavefunctions (in an outer loop) in combination 
with updating the electron occupancy (in an inner loop). As you I am also 
trying to optimize the atomic structure of a cluster placed inside vacuum in a 
box. My computational facility is limited. So, till now I have only been able 
to simulate till 0.1 ps. So far the change in atomic structure from the input 
perfect crystal-fragment is reasonable. 

However I am getting a note, 

NOTE : eigenvalues are not computed without ortho 
And the reported eigenvalues are all zeros 

I am concerned with this NOTE as, I think the eigen values are required to 
calculate the smearing of the electrons. 

So, today my question to you is the following. Did you get this NOTE too? 

Thank you, 
Best regards, 
Krishnendu 


-----------------------------------------------------------------------------------you
 wrote: 

It is a cluster inside a 20 A box to remove periodicity. But that cluster 
is a part of large MD simulated position coordinates file of 10000 atoms. 

Thank you 
Regards 
Jayraj Anadani 

On Sun, 2 Oct, 2022, 10:15 am KRISHNENDU MUKHERJEE, <krishnendu at 
nmlindia.org> 
wrote: 

> 
> Dear Dr. Jayraj Anadani, 
> 
> Is your input atomic structure is a cluster inside vacuum in a box or it 
> is a supercell? 
> 
> Thank you, 
> Regards, 
> Krishnendu 
> 
> 
> -------------------------------------------------------------------------------------------------
>  
> You wrote: 
> In my case, I have a system of 54 zrcu atoms. i want to melt it at higher 
> temperatures above 2000K and then i will do quenching to get amorphorse 
> metallic alloys state. 
> But shorter time step in cg method give more time consuming. So i choose dt 
> = between 30 to 60 and in order to get equilibrium at high temperatures i 
> took nstep = above 500. 
> For equilibrium i have to run continue till 3 to 5 ps to get randomisation 
> so it took large time to complete. 
> Any suggestions ? 
> 
> Thank you 
> Jayraj Anadani 


_______________________________________________
The Quantum ESPRESSO community stands by the Ukrainian
people and expresses its concerns about the devastating
effects that the Russian military offensive has on their
country and on the free and peaceful scientific, cultural,
and economic cooperation amongst peoples
_______________________________________________
Quantum ESPRESSO is supported by MaX (www.max-centre.eu)
users mailing list users@lists.quantum-espresso.org
https://lists.quantum-espresso.org/mailman/listinfo/users

Reply via email to