Re: [ovirt-users] Regression in Gluster volume code?

2015-12-17 Thread noc
On 16-12-2015 17:06, Sahina Bose wrote: > > > https://bugzilla.redhat.com/show_bug.cgi?id=1292173 Thanks. Will have a look at it and amend if needed. Joop ___ Users mailing list Users@ovirt.org http://lists.ovirt.org/mailman/listinfo/users

Re: [ovirt-users] Regression in Gluster volume code?

2015-12-16 Thread Joop
On 15-12-2015 12:31, Sahina Bose wrote: > > > On 12/15/2015 03:26 PM, Joop wrote: >> On 14-12-2015 12:00, Joop wrote: >>> I have reinstalled my test environment have come across an old error, >>> see BZ 988299, Bad volume specification {u'index': 0,. >>> >>> At the end of that BZ there is

Re: [ovirt-users] Regression in Gluster volume code?

2015-12-16 Thread Sahina Bose
On 12/16/2015 09:20 PM, Joop wrote: On 15-12-2015 12:31, Sahina Bose wrote: On 12/15/2015 03:26 PM, Joop wrote: On 14-12-2015 12:00, Joop wrote: I have reinstalled my test environment have come across an old error, see BZ 988299, Bad volume specification {u'index': 0,. At the end of that

Re: [ovirt-users] Regression in Gluster volume code?

2015-12-15 Thread Joop
On 15-12-2015 12:31, Sahina Bose wrote: > > > On 12/15/2015 03:26 PM, Joop wrote: >> On 14-12-2015 12:00, Joop wrote: >>> I have reinstalled my test environment have come across an old error, >>> see BZ 988299, Bad volume specification {u'index': 0,. >>> >>> At the end of that BZ there is

Re: [ovirt-users] Regression in Gluster volume code?

2015-12-15 Thread Joop
On 14-12-2015 12:00, Joop wrote: > I have reinstalled my test environment have come across an old error, > see BZ 988299, Bad volume specification {u'index': 0,. > > At the end of that BZ there is mentioning of a problem with '_' in the > name of the volume and a patch is mentioned but the code

Re: [ovirt-users] Regression in Gluster volume code?

2015-12-15 Thread Sahina Bose
On 12/15/2015 03:26 PM, Joop wrote: On 14-12-2015 12:00, Joop wrote: I have reinstalled my test environment have come across an old error, see BZ 988299, Bad volume specification {u'index': 0,. At the end of that BZ there is mentioning of a problem with '_' in the name of the volume and a

[ovirt-users] Regression in Gluster volume code?

2015-12-14 Thread Joop
I have reinstalled my test environment have come across an old error, see BZ 988299, Bad volume specification {u'index': 0,. At the end of that BZ there is mentioning of a problem with '_' in the name of the volume and a patch is mentioned but the code has since been change quite a bit and I