Hi,
Indeed at this stage it is not supported to have VM and VLAN networks on the
same physical interface.
I know it is supposed to be changed in the future (if I understand correctly it
is already supported on the VDSM side).
For now you can have 2 VLAN networks on the same interface ( so if it
Hi,
Indeed for ISCSI Bond the network should be non-required.
You should change your network to be non-required, then it will work for you
Go to Cluster - choose specific Cluster you are working on - Go to Logical
Network subtab - Go to Managed network and uncheck the required flag.
Genadi
You are welcome
Genadi
- Original Message -
From: Arthur Cezar Lima de Melo arthur.m...@gigacom.com.br
To: Genadi Chereshnya gcher...@redhat.com
Cc: Yaniv Dary yd...@redhat.com, users@ovirt.org
Sent: Wednesday, July 1, 2015 3:06:07 PM
Subject: Re: [ovirt-users] oVirt iSCSI
Oh,
Thank
RFE link: https://bugzilla.redhat.com/show_bug.cgi?id=1234302
You are welcome to update it if needed
Genadi
- Original Message -
From: Punit Dambiwal hypu...@gmail.com
To: Genadi Chereshnya gcher...@redhat.com
Cc: users@ovirt.org, Dan Kenigsberg dan...@redhat.com, Omer Frenkel
ofren
Hi Punit.
About your first question: There is a new feature in 3.6 called cumulative
rx/tx statistics
I think this is what you need. Please take a look at the feature page:
http://www.ovirt.org/Features/Cumulative_RX_TX_Statistics
About you second question: I am not aware of such a feature, so
Dambiwal hypu...@gmail.com
To: Genadi Chereshnya gcher...@redhat.com
Cc: users@ovirt.org, Dan Kenigsberg dan...@redhat.com, Omer Frenkel
ofren...@redhat.com, Itamar Heim ih...@redhat.com
Sent: Monday, June 22, 2015 11:57:41 AM
Subject: Re: [ovirt-users] VM Bandwidth Consumption
Hi Genadi,
Thanks
I am glad you figured out what the problem is
Genadi
- Original Message -
From: Andrew Precht andrewprech...@gmail.com
To: Genadi Chereshnya gcher...@redhat.com, Users@ovirt.org
Sent: Thursday, May 28, 2015 8:01:19 PM
Subject: Re: [ovirt-users] connecting my oVirt engine to a 100mb switch
Hi Jorick,
I am not sure that Network_Custom_Properties is what you are looking for.
With network custom properties you can only configure bridge or ethtool opts.
So bridge opts doesn't suit you as it is only for specific configuration of the
bridge on the specific NIC
and with ethtool you don't
Hi Chris,
If I understand you correctly you are trying to replace the physical device
mirroring with VM?
If this is the case I don't think it's possible to do it with port mirroring
oVIRT feature.
The existing oVIRT port mirroing feature is for mirroring traffic between VM
devices for specific
Engine will need only one network card
Hosts will need 3 if you use untagged traffic for your requirements
Genadi
- Original Message -
From: Simone Tiraboschi stira...@redhat.com
To: nicola gentile nicola.gentile...@gmail.com
Cc: Users@ovirt.org
Sent: Thursday, January 15, 2015 11:11:06
Hi,
We would like to propose a little bit better solution from user experience side.
We should have 3 fields for each range:
1) Start range
2) End range
3) Number of MACs
When you have to fill in End range or Number of MACs (when start range is
mandatory).
And the 3rd field will be filled in
) and to reduce them
from the count of Number of MACs
Genadi
- Original Message -
From: Martin Mucha mmu...@redhat.com
To: Genadi Chereshnya gcher...@redhat.com
Cc: Moti Asayag masa...@redhat.com, de...@ovirt.org, users@ovirt.org,
Martin Pavlik mpav...@redhat.com
Sent: Monday, April 28, 2014 9
Hi,
We installed the new ovirt-engine-sdk-python from Fedora repo - version
3.3.0.7-1.fc20
The VNIC profile collection was missing under API root.
Installing it from nightly (version
ovirt-engine-sdk-python-3.5.0.0-1.20140211.git61ac75b.fc20.noarch) had the same
result.
According to
I found out that my PYTHONPATH was directing to outdated sources (cloned from
an early version),
therefore the rpms were hidden.
Once, I unset the PYTHONPATH, the issue was solved and the correct SDK package
was used.
Thanks,
Genadi
- Original Message -
From: Genadi Chereshnya gcher
Hi all,
We would like to consult community about adding the Network from Cluster tab.
In 3.3 we can add Network from the DataCenter tab and then that network will be
attached to all Clusters of that DataCenter.
When adding network from specific Cluster the default behavior today is to
attach
15 matches
Mail list logo