[Users] Ims shared disks and ovirt storage

2013-04-09 Thread Gianluca Cecchi
Hello,
I have the chance to work on Intel blades where I have option to confihure
shared disks between them at enclosure level.
Their controller is scsi.
How could I configure as shared storage in ovirt?
I presume neither Fc nor iscsi are possible. .. so what can i do in your
opinion?
Thanks in advance
Gianluca
___
Users mailing list
Users@ovirt.org
http://lists.ovirt.org/mailman/listinfo/users


Re: [Users] Ims shared disks and ovirt storage

2013-04-09 Thread Koch (ovido)
Hi Gianluca,


On Tue, 2013-04-09 at 12:50 +0200, Gianluca Cecchi wrote:
 Hello, 
 I have the chance to work on Intel blades where I have option to
 confihure shared disks between them at enclosure level.
 Their controller is scsi.
 How could I configure as shared storage in ovirt? 
 I presume neither Fc nor iscsi are possible. .. so what can i do in
 your opinion? 


Is this an Intel modular server, btw?
If yes - create a Fibre channel datacenter and add the storage as FC
LUNs. I can also send you a working multipath.conf for Intel Modular if
required...


Regards,
René


 Thanks in advance
 Gianluca
 
 ___
 Users mailing list
 Users@ovirt.org
 http://lists.ovirt.org/mailman/listinfo/users

___
Users mailing list
Users@ovirt.org
http://lists.ovirt.org/mailman/listinfo/users


Re: [Users] Ims shared disks and ovirt storage

2013-04-09 Thread Gianluca Cecchi
On Tue, Apr 9, 2013 at 1:56 PM, René Koch (ovido)  wrote:
 Hi Gianluca,


 On Tue, 2013-04-09 at 12:50 +0200, Gianluca Cecchi wrote:
 Hello,
 I have the chance to work on Intel blades where I have option to
 confihure shared disks between them at enclosure level.
 Their controller is scsi.
 How could I configure as shared storage in ovirt?
 I presume neither Fc nor iscsi are possible. .. so what can i do in
 your opinion?


 Is this an Intel modular server, btw?
 If yes - create a Fibre channel datacenter and add the storage as FC
 LUNs. I can also send you a working multipath.conf for Intel Modular if
 required...


 Regards,
 René


Yes, it is an Intel modular server (I don't know well this platform
but I think IMS is its acronym)
The multipath working configuration would be more than appreciated ;-)
But does this mean there are configuration with dual scsi or is
multipath needed in every case (as I see oVirt config implies
multipath configuration anyway.)

Gianluca
___
Users mailing list
Users@ovirt.org
http://lists.ovirt.org/mailman/listinfo/users


Re: [Users] Ims shared disks and ovirt storage

2013-04-09 Thread Koch (ovido)

On Tue, 2013-04-09 at 13:59 +0200, Gianluca Cecchi wrote:
 On Tue, Apr 9, 2013 at 1:56 PM, René Koch (ovido)  wrote:
  Hi Gianluca,
 
 
  On Tue, 2013-04-09 at 12:50 +0200, Gianluca Cecchi wrote:
  Hello,
  I have the chance to work on Intel blades where I have option to
  confihure shared disks between them at enclosure level.
  Their controller is scsi.
  How could I configure as shared storage in ovirt?
  I presume neither Fc nor iscsi are possible. .. so what can i do in
  your opinion?
 
 
  Is this an Intel modular server, btw?
  If yes - create a Fibre channel datacenter and add the storage as FC
  LUNs. I can also send you a working multipath.conf for Intel Modular if
  required...
 
 
  Regards,
  René
 
 
 Yes, it is an Intel modular server (I don't know well this platform
 but I think IMS is its acronym)


You can contact me if you have questions regarding these server - I
use(d) this system in the company I worked before and on customer side.


 The multipath working configuration would be more than appreciated ;-)
 But does this mean there are configuration with dual scsi or is
 multipath needed in every case (as I see oVirt config implies
 multipath configuration anyway.)

Attached is a working multipath.conf for RHEV-H 3.0.
You need a working multipath.conf file if you have redundant storage
controllers.

Find out the wwids of your devices and add them to your
blacklist_exceptions section.

# multipath -ll
mpathb (b00015521f5d4) dm-0 Intel,Multi-Flex
size=96G features='0' hwhandler='0' wp=rw
|-+- policy='round-robin 0' prio=50 status=active
| `- 0:0:0:1 sdb 8:16 active ready running
mpatha (222140001553601d1) dm-1 Intel,Multi-Flex
size=20G features='0' hwhandler='0' wp=rw
|-+- policy='round-robin 0' prio=50 status=active
| `- 0:0:0:0 sda 8:0  active ready running

Don't forget to persist /etc/multipath.conf if you're using ovirt-node!
With this config you don't need the Intel multipath drivers, btw.

Please let me know if you have further questions.


 
 Gianluca
# RHEV REVISION 0.7
# RHEV PRIVATE

defaults {
udev_dir/dev
polling_interval10
path_selector   round-robin 0
path_grouping_policymultibus
getuid_callout  /lib/udev/scsi_id --whitelisted 
--device=/dev/%n
prioalua
path_checkerreadsector0
rr_min_io   100
max_fds 8192
rr_weight   priorities
failbackimmediate
no_path_retry   fail
user_friendly_names yes
}
blacklist {
   wwid 26353900f02796769
devnode ^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*
devnode ^hd[a-z]
}
blacklist_exceptions {
wwid b00015521f5d4
wwid 222140001553601d1
}
devices {
device {
vendor  Intel
product Multi-Flex
path_grouping_policygroup_by_prio
getuid_callout  /lib/udev/scsi_id --whitelisted 
--device=/dev/%n
priotpg_pref
path_checkertur
path_selector   round-robin 0
hardware_handler1 alua
failbackimmediate
rr_weight   uniform
rr_min_io   100
no_path_retry   queue
features1 queue_if_no_path
product_blacklist VTrak V-LUN
}
}
multipaths {
multipath {
uid 0
alias mpatha
gid 0
wwid 222140001553601d1
mode 0600
}
multipath {
uid 0
alias mpathb
gid 0
wwid b00015521f5d4
mode 0600
}
}___
Users mailing list
Users@ovirt.org
http://lists.ovirt.org/mailman/listinfo/users