Hi,
I also raised a bug with power management, but I have issues with Cisco UCS!
There is a bug starting with ovirt engine 4.0.5, where the "Options" field only
allows integers anymore!
I was told, they want to fix this in 4.0.7 ->
I was able to solve the issue by using the API. The api accepted the input
and the Power Management is working now. I am still not sure why the Web Ui
is not working but atleast i can move on now. Thank you for all your help!
Thanks,
Bradley Bishop
On Mon, Jan 23, 2017 at 5:32 PM, Torsten
Hello Bradley,
beats me - I tried to replicate your situation but was unable to reach
that error. My setup seems identical to yours (Centos 7.3 / oVirt Engine
4.0.2.7-1).
Is it possible that this error is related to some totally different field?
Out of ideas,
Torsten
On 23.01.2017 23:08,
Hello Torsten,
Thank you for replying! I read that somewhere else also. The issue is web
ui does not allow me to enter those options. I get an error that states
"The field must contain an integer number between -2147483648
<(214)%20748-3648> and 2147483648 <(214)%20748-3648>."
Thank you,
Bradley
Hello Bradley,
I am successfully managing an R710 drac6 controller using the following
parameters:
Type: drac5
Options: cmd_prompt=/admin1->,login_timeout=60
Hope this helps,
Torsten
On 23.01.2017 22:43, Bradley Bishop wrote:
Hello all,
I am new to ovirt and having issues setting up
5 matches