Hi,
I would suspect this to happen when the probe times out somehow (due to the
network issues etc.) or simply it cannot detect the VM at the moment. Does the
VM remain in 'poweroff' state forever or does it become 'running' again after
some time?
Ondra
From: Users
Hi
This problem is as described by Ondra becasue of a kind of race condition
between the boot process and the monitor probes. You may or may not see it
depending on timing network and the like.
OpenNebula 4.10.2 includes some logic to deal with this and also to recover
automatically the VM when