Dear All,
I am very new to Quantum Espresso. I want to get a charge density
difference plot for a gas molecule adsorbed on the single layer graphene
surface. Presently I am using pp.x to compute the same in QE v.5.1
following an equation:
∆ρ=ρAB – ρA-ρB
Where, ρAB, ρA and ρB are the charge
Dear Christoph
I suppose that you can filter out the R0 translation to obtain the
autocorrelation of the dipole moment across the trajectory.
> Total0.2108 -0.36230.1151 au, 0.5358 -0.9209
> 0.2925 Debye
before FFT the autocorrelation function you may also try to
you need to compute the three charges with the same parameters
stefano
On 12/08/2017 16:20, Bibhas Manna wrote:
Dear All,
I am very new to Quantum Espresso. I want to get a charge density
difference plot for a gas molecule adsorbed on the single layer
graphene surface. Presently I am using
Dear Sir,
Thanking you for your quick reply.
I have used the same parameter for three charges. Following are the input
pp.x files:
*For Substrate + molecules:*
prefix = 'PG_4_HCHO_PBE'
outdir = './tmp/'
filplot = 'PG_4_HCHO_charge'
plot_num= 0
/
nfile = 1
filepp(1)
I'm no expert, but I think you need to make the scf calculations with
the same parameters, especially ecutrho and CELL_PARAMETERS.
Matthieu
Bibhas Manna a écrit :
> Dear Sir,
>
> Thanking you for your quick reply.
>
> I have used the same parameter for three charges.
On 12/08/2017 16:52, Matthieu Fortin-Deschênes wrote:
> I'm no expert, but I think you need to make the scf calculations with
> the same parameters, especially ecutrho and CELL_PARAMETERS.
>
> Matthieu
exactly. stefano
>
> Bibhas Manna a écrit :
>
>> Dear Sir,
>>
>>
Dear Matthieu,
Since, I have done the geometry relaxation using *vc-relax,* how can I
maintain the same *Cell_Parameters* for all the three cases.
Thanks.
Bibhas
On Sat, Aug 12, 2017 at 8:22 PM, Matthieu Fortin-Deschênes <
matthieu.fortin-desche...@polymtl.ca> wrote:
> I'm no expert, but I
you take the final vc-relaxed cell and assume the same for the two
separate fragments.
And you need to redo the scf calculation (only the scf calculation) of
the combined system so as to have the same parameters for all three.
stefano
On 12/08/2017 17:04, Bibhas Manna wrote:
Dear Matthieu,
Good evening,
I am encountering an error I know not how to resolve as a namelist error
(Error in routine read_namelists (19):). I do not believe I lack any
commas as needed, but clearly I do not appreciate my syntax error.
calculation = "relax"
Hi Robert,
You need only for
* 'vc-relax' or 'vc-md.*
You don't need that name list for 'relax' calculation.
Regards,
Isaiah
On Sat, Aug 12, 2017 at 8:39 PM, Robert Molt <
r.molt.chemical.phys...@gmail.com> wrote:
> Good evening,
>
> I am encountering an error I know not how to resolve as a
On Sat, Aug 12, 2017 at 9:39 PM, Robert Molt <
r.molt.chemical.phys...@gmail.com> wrote:
>
> I am encountering an error I know not how to resolve as a namelist error
> (Error in routine read_namelists (19):). I do not believe I lack any
> commas
you lack for sure some " or ' here:
Good evening,
I am confused on the rules for the quotes. The below is another file I
used for calculation (a vx-relax, which is why I left some of those
fields for the previously posted input file), which ran just fine. In
this one, I did not use quotes around many of the items in and
it
12 matches