Hi,
I have working Power Management on Dell PowerEdge R820. The
configuration is following:
Type: drac7
Options: key='$value'
where $value should be set the same as following setting in iDRAC:
iDRAC Settings - Network - IPMI Settings - Encryption Key
Regards,
Piotr
W dniu 01.06.2015 o
Le 01/06/2015 20:44, Juan Carlos YJ. Lin a écrit :
Need help to configure Dell R720 IPMI, tested with drac5, drac7 but all
result in unknow status
Options : lanplus=1
--
Nicolas Ecarnot
___
Users mailing list
Users@ovirt.org
Nicolas,
We have newer Dell working with the following setting:
type: drac5
slot:
options: cmd_prompt=
secure: checked
Works fine for us. Even on the new Dell FC630’s this configuration is working.
-Patrick
On Jun 1, 2015, at 2:12 PM, Nicolas Ecarnot nico...@ecarnot.net wrote:
Le
3 matches