Hi Masoud,

Please refrain from creating multiple threads on the same topic. [1][2][3]

Have you tried the suggestion that Marcus Leech suggested in your original 
post? [4] You're still operating with n_channel = 1, when it should be 
n_channel = 2;


[1] - 
http://lists.ettus.com/pipermail/usrp-users_lists.ettus.com/2017-August/025991.html
[2] - 
http://lists.ettus.com/pipermail/usrp-users_lists.ettus.com/2017-August/026030.html
[3] - 
http://lists.ettus.com/pipermail/usrp-users_lists.ettus.com/2017-August/026031.html

[4] - 
http://lists.ettus.com/pipermail/usrp-users_lists.ettus.com/2017-August/025898.html


Please use this thread for follow up on this issue.

Regards,
Nate Temple


> On Aug 9, 2017, at 12:04 PM, Masoud Naderpour via USRP-users 
> <usrp-users@lists.ettus.com> wrote:
> 
> Hi,
> I have launched B210 USRP MIMO config. I have problem in transmission on both 
> Tx channels. However, there is no problem in receiving on both ones. In 
> transmission on both channels continous Underflows appear in console. It is 
> independent of the Tx sampling rate. How can I fix the problem?
> I have used the following code for initializing the uhd stream. 
> 
> size_t channel[2] = { 0,1 };;
> uhd_stream_args_t stream_args = {
> cpu_format = "fc32",
> otw_format = "sc16",
> args = "",
> channellist = channel,
> n_channel = 1
> };
> How can I fix the problem?
> _______________________________________________
> USRP-users mailing list
> USRP-users@lists.ettus.com
> http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com


_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com

Reply via email to