[Veritas-bu] Can we use NDMP storage unit to backup regular windows clients?

2006-01-25 Thread Sto Rage©
We have a master server that connects to a SL500 robot. The drives in the SL500 library are all directly conencted to a Netapp. We have been using this to backup the netapp over NDMP. So far so good. Can this setup be extended to backup widows clients? We are running version 6 of NBU. We want to av

Re: [Veritas-bu] Request for feedback on NetBackup 6.0 MP1

2006-01-25 Thread Karl . Rossing
In case you missed it In-Depth Troubleshooting Guide for Exit Status Code 41 in NetBackup Server (tm) / NetBackup Enterprise Server (tm) 6.0 http://seer.support.veritas.com/docs/278422.htm Karl [EMAIL PROTECTED] wrote on 01/25/2006 01:50:40 PM: > We're in the process of moving from our 4.5FP8

Re: [Veritas-bu] Request for feedback on NetBackup 6.0 MP1

2006-01-25 Thread william . d . brown
You don't mention the server platform, but we've been warned (and found) that our Solaris servers need to be up to date on Kernel patches to avoid problems, just going to 5.1. I realise 6.0 is very different, but I suggest that at least if you use Solaris it is likely to still be true. William

Re: [Veritas-bu] Request for feedback on NetBackup 6.0 MP1

2006-01-25 Thread Steve Quan
We're in the process of moving from our 4.5FP8 system to 6.0MP1 (everythin new). The major problem we're seeing, are ERROR 41's as we start "loading up" the media servers. These would occur in batches and appear on the more heavily loaded media server. Any 6.0 environments out there experiencing t

Re: [Veritas-bu] anyone using Sun/Qlogic HBAs and LTO2/3 tapes?

2006-01-25 Thread william . d . brown
Indeed in our test lab I've used the Qlogic card with the QLogic driver, which is what ADIC recommend. No issues at all but I don't have enough hardware to test SSO intensively.The latest Qlogic driver is dynamically reconfigurable - it says - as long as you use their tools to do so, and a

RE: [Veritas-bu] Request for feedback on NetBackup 6.0 MP1

2006-01-25 Thread Jim Peppas
Not bad for starters but my company enviroment is rather small (1 Master/media and about 10 clients). I have also setup NOM and have setup reports and notifications. Anyone else implemented NOM? Regards, Jim -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf

RE: [Veritas-bu] Netbackup Vault Manager Service not starting

2006-01-25 Thread Jim Peppas
Hi. I have also upgraded to 6.0 . I think that if you don't have the Vault Licence it wont go up. Not sure though... Regards, Jim -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Parnell, Bill Sent: Wednesday, January 25, 2006 6:32 PM To: veritas-bu@mail

RE: [Veritas-bu] Media id's not appearing in NB media database

2006-01-25 Thread Jim Peppas
Hi. When you add a tape, it will appear in the in the vmquery output, but not in the bpmedialist command output. It will appear in the bpmedialist command output when it has been used in a succesfull backup. The vmquery -deassignbyid command is VERY bad way to go. It will cause major mismatches

Re: [Veritas-bu] anyone using Sun/Qlogic HBAs and LTO2/3 tapes?

2006-01-25 Thread Jack L. Forester, Jr.
Sun really seems to be dragging their feet when it comes to support for any FC tape. We started with FC tape with SGI servers over 4 years ago. No problem. Same thing for HP-UX. We also had a couple of Sun 420R boxes with Sun/qlogic HBAs which refused to recognize the STK drives we had. Th

[Veritas-bu] Request for feedback on NetBackup 6.0 MP1

2006-01-25 Thread Tarik El Mansouri
All, Has anyone already upgraded its NetBackup solution from 5.1 MP3 to 6.0 MP1 ? My customer environment is composed of Windows 2003 servers, Exchange clusters, SQL and Notes databases. Veritas Security Services are also implemented on the master server. Any feedback will be appreciated. Best

[Veritas-bu] Netbackup Vault Manager Service not starting

2006-01-25 Thread Parnell, Bill
Hi there, I have just recently upgraded from Netbackup Enterprise version 5.1MP3 to 6.0MP1 After the upgrade that went without a hitch the Netbackup Vault Manager Service refuses to start up. I am not using vault and do not have a licence for it but the service is listed and will not start! It

Re: [Veritas-bu] Backup to Disk

2006-01-25 Thread Peter DrakeUnderkoffler
-BEGIN PGP SIGNED MESSAGE- Hash: SHA1 That would be the Advanced Client with the Off Host Backups. A separately licensed item. Thanks Peter DrakeUnderkoffler Xinupro, LLC 617-834-2352 Martin, Jonathan (Contractor) wrote: > > We just upgraded out SAN Solution to something with 80TB

Re: [Veritas-bu] anyone using Sun/Qlogic HBAs and LTO2/3 tapes?

2006-01-25 Thread william . d . brown
Yes, though there is almost nothing you can tune. Search on the internet for the document entitled "San Foundation Suite Tunables". We have also found that our library vendor does not actually support using the qlc driver with their libraries, as it does not comply with the fibre-channel stand

[Veritas-bu] Backup to Disk

2006-01-25 Thread Martin, Jonathan \(Contractor\)
Title: Message   We just upgraded out SAN Solution to something with 80TB or similar, and the possibility now exists of using our Hitachi AMS500 to run shadow copies, hot copies or whatever you would like to call it.  Unfortunately, it would be a major pain in the rear to have to manually hav

RE: [Veritas-bu] recommended LTO2 drive fragment size?

2006-01-25 Thread George Drew
I would recommend that 2Gb is probably not a large enough fragment size, as that's barely long enough for the drive to get up to speed. Figure 70MB/sec transfer rate (optimally), and your drive is stopping every 4 minutes (roughly). Add multi-plexing and that could be even more often, not to men

Re: [Veritas-bu] Media id's not appearing in NB media database

2006-01-25 Thread Steven L. Sesar
The problem that the original poster was/is having, is that the media in question exists in the volume database on the master server, but not in any media database. This means, that unless his scratch pool is MISPD, this tape will never be utilized in its current state, since it is marked "assi

RE: [Veritas-bu] recommended LTO2 drive fragment size?

2006-01-25 Thread Casoli Marco
Hello   Look at the Veritas-Document #262724 (How to optimally performance-tune systems with IBM Linear Tape-Open 2 drives) Notice: You must have enough physical und shared memory on your system.   And your question: We use the follow fragmentsize (2000 MB) Marco Casoli IT-Systemspezialist St

RE: [Veritas-bu] Media id's not appearing in NB media database

2006-01-25 Thread Barber, Layne \(Contractor\)
Tried the vmquery and here is what I got vmquery -m dou079 Could not query by media ID DOU079: volume does not exist in database (35) -Original Message- From: Spearman, David [mailto:[EMAIL PROTECTED] Sent: Wednesday, January 25, 2006 07:58 To: Barber, Layne (Contractor); Robert Nusser;

RE: [Veritas-bu] Media id's not appearing in NB media database

2006-01-25 Thread Spearman, David
I had the same thing happen and got a solution from Veritas (excuse me, symantec). It is drastic but it does work. You need to know the tape ID and the pool number. install_path\volmgr\bin\vmquery.exe -deassignbyid 0 (that's a zero, use on a tape that is NOT a catalog) install_path\volmgr\bin

RE: [Veritas-bu] Media id's not appearing in NB media database

2006-01-25 Thread Barber, Layne \(Contractor\)
I have a similar situation. I have a tape that shows up in the media list in the gui, but I can't delete it or anything. I get the message that the volume is not in the NB database. -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Robert Nusser Sent: Wedne

[Veritas-bu] recommended LTO2 drive fragment size?

2006-01-25 Thread Barber, Layne \(Contractor\)
Any recommendations for the fragment size when using LTO2 drives? Any other tuning tips for a 5.1 setup using LTO2.  

[Veritas-bu] anyone using Sun/Qlogic HBAs and LTO2/3 tapes?

2006-01-25 Thread Paul Keating
Title: Message I've been looking for some performance tuning infolike tuning the HBAs block transmit to match the drives, etc, etc   Can't seem to find anything.worse case, I can go to Sun     Paul

[Veritas-bu] Media id's not appearing in NB media database

2006-01-25 Thread Robert Nusser
Hi all, I am having problems with some of my media id's not appearing in the "NB media database". I have attempted bplabeling the tape again, and then assigning it with vmquery -assignbyid. Alas it seems I am back where I started and I can see the tape using vmquery, but I cannot see the tape usin

SV: [Veritas-bu] Master and Media HW and OS..

2006-01-25 Thread Hampus Lind